9.
TROUBLESHOOTING
PROBLEM
Unit fails to start
LCD does not
light
Air Cylinder does
not move
The hardener is
not completely
injected
The injection rod
does not retract
Material is not
completely mixed
Cartridge holder
is not in "Home''
position
Mixing rod does
not reach spindle
No pressure on
plunger
24
POSSIBLE CAUSE
• No power input
• Emergency button
is pressed
• Safety door is not
fully closed
• No power input
• Insufficient air
pressure
• Air hoses not
plugged in
• Regulator defective
• Air cylinder is
damaged
• Injection rod is
dirty
• Injection rod is
bent
• Not enough mixing
cycle
• Insufficient air
pressure
• Insufficient air
pressure
• Air hoses not
plugged in
• Extension spindle is
not installed for 6
rod
• Mixing rod in not
fully extended
• Plunger air hose is
not connected
CORRECTION
• Check power
connections
• Release Emergency
stop button
• Close safety door
• Check power
connections
• Check Fuse
• Turn on power
• Increase air pressure
to 80 psi (5.5 bar)
• Check air connection
• Replace regulator
• Replace air cylinder
• Clean rod
• Replace rod
• Increase number of
cycles
• Increase air pressure
to 80 psi
• Increase supply
pressure to 80 psi (5.5
bar)
• Check air connection
• Install extension
''
spindle for 6
• Extend mixing rod
• Connect plunger air
hose
rod
''
Produits Connexes pour TECHCON TS6500CIM