7.7
Mix Cycle Program Setup
Refer to Fig. 4.0.
1. Press the Mode button to select Auto mode.
2. Press and hold the Setup button for 3 seconds to enter setup
screen.
3. Press the Setup button to move the cursor to the
"CYCLE'' indicator.
4. Press the (+) and (-) button to set number of mix cycles required.
5. If a delay time is required, press the Setup button to move the
cursor to the "DELAY'' indicator then press the (+) and (-) button
to adjust delay time, for up stroke and down stroke. (Fig. 5.0 D:
Down / U: Up)
6. Press and hold the Setup button for 3 seconds to save data. The
unit is now ready to run.
7.8
Start the Unit
1. Ensure the unit is in the Automatic Mode and the desired
profile has been selected.
2. Press and release the Start buttons (Green) (Fig 2.0, 7)
simultaneously.
3. The unit will run the selected profile. The cycle count and
elapsed time will be displayed on the LED screen.
7.9
Unloading the Cartridge Kit
1.
2.
21
The machine will automatically stop once the mixing
cycles are completed.
Open the protective cover (Fig. 2.0, 12).