DESCRIPTION
Emergency
Stop button
(Red)
LCD Display
Protective
(Safety) Cover
Plunger Disk
Fluid Level
Sensor
Fluid Level
Magnet
Plunger
Assembly
Flow Control;
Main Cylinder
Flow Control;
Injection Rod
Voltage Select
Switch
Power Input
Socket with
Fuse Box
Air Filter
Wrench
Accessories
Bracket
Cartridge
Holder Bracket
12
FUNCTION
•
Stops the Unit in an Emergency
•
Press to Engage
•
"E-Stop!'' will be displayed,
•
To reset, rotate the E-Stop knob a quarter
turn clockwise
•
Displays unit status, operation and error
messages.
•
Protects operators when machine is
in use
•
Part of Plunger Assembly
•
Senses the fluid level at the top of
the cartridge
•
Works with fluid level sensor
•
Locks cartridge in place
•
Applies steady pressure to prevent
air entrapment
•
Controls the speed of the main cylinder
•
Rotate the flow control screw clockwise
to increase the speed.
•
Rotate the flow control screw
counterclockwise to decrease the speed
•
Controls the speed of the injection rod
•
Rotate the flow control screw clockwise
to increase the speed.
•
Rotate the flow control screw
counterclockwise to decrease the speed
•
Select 115V or 230V
•
Input power connection
•
Provides air filtration
•
Used to install the air filter assembly and
drive spindle assembly
•
To hold wrench or other accessories
•
To hold extra cartridge holder