DESCRIPTION
Emergency
Stop button
(Red)
LCD Display
Protective
(Safety) Cover
Plunger Disk
Fluid Level
Sensor
Fluid Level
Magnet
Plunger
Assembly
Flow Control;
Main Cylinder
Flow Control;
Injection Rod
Voltage Select
Switch
Power Input
Socket with
Fuse Box
Air Filter
Wrench
Accessories
Bracket
Cartridge
Holder Bracket
12
FUNCTION
Stops the Unit in an Emergency
Press to Engage
"E-Stop!'' will be displayed,
To reset, rotate the E-Stop knob a quarter
turn clockwise
Displays unit status, operation and error
messages.
Protects operators when machine is
in use
Part of Plunger Assembly
Senses the fluid level at the top of
the cartridge
Works with fluid level sensor
Locks cartridge in place
Applies steady pressure to prevent
air entrapment
Controls the speed of the main cylinder
Rotate the flow control screw clockwise
to increase the speed.
Rotate the flow control screw
counterclockwise to decrease the speed
Controls the speed of the injection rod
Rotate the flow control screw clockwise
to increase the speed.
Rotate the flow control screw
counterclockwise to decrease the speed
Select 115V or 230V
Input power connection
Provides air filtration
Used to install the air filter assembly and
drive spindle assembly
To hold wrench or other accessories
To hold extra cartridge holder