b-5. Type setting
With the keys
Press
again: the value flashes and can be modified
With the keys
c.) pH measurement menu:
With the keys
Press
to enter the menu
Once the settings of this menu are done, press
c-1. pH Setpoint setting
With the keys
Press
again: the value flashes and can be modified
With the keys
c-2. Sp type setting (Dose product, acid or basic)
With the keys
Press
again: the value flashes and can be modified
With the keys
c-3. OFA time setting (Over Feeding Alarm=Overdose alarm)
Displays "OFA alarm" and stops the pH injection if there is no variation in pH after 40 minutes of the
injection cycles. Do not change it until you have controlled the correct operation of the probe.
With the keys
40mnACID)
Press
again: the value flashes and can be modified
With the keys
c-4. ALR Band setting
With the keys
Press
again: the value flashes and can be modified
With the keys
c-5. Temperature setting
With the keys
Press
again: the value flashes and can be modified
With the keys
Combipool-pHRedox_(Multi) - DOC015452 - Ind. A03 - 23/12/2020
Marque, Modèles et Brevets déposés - Produits exclusifs
or
, select "Type", the current value is displayed on the side (by default: PROP)
or
, set the desired new value and then press
or
, select "pH measure"
or
, select "Setpoint", the current value is displayed on the side (by default: 7.3pH)
or
, set the desired new value and then press
or
, select "Dosing", the current value is displayed on the side (by default: ACID)
or
, set the desired new value and then press
or
, select "OFA time", the current value is displayed on the side (by default:
or
, set the desired new value and then press
or
, select "ALR band", the current value is displayed on the side (by default: 1.0)
or
, set the desired new value and then press
or
, select "Temp", the current value is displayed on the side (by default: 25)
or
, set the desired new value and then press
to validate
to return to "Program Menu"
to validate
to validate
to validate
to validate
to validate
Copyright BIO-UV