G. THREE ESSENTIAL STEPS
1. Water balance
TAC must be maintained at least at
The stabilizer rate should be lower than 15ppm
2. Filtration
Weekly filter washing
Annual disinfection and descaling of the sand filter
Permanent flocculation (for sand filters)
3. Anti-algae treatment: The Redox setpoint at 720mV should maintain a
free chlorine rate at a minimum of 1 ppm
UV-C sterilizer + Redox = Effective curative and preventive action
Combipool-pHRedox_(Multi) - DOC015452 - Ind. A03 - 23/12/2020
Marque, Modèles et Brevets déposés - Produits exclusifs
pH must be maintained at 7.2 
15°F/150mg/l
Adjust pH setpoint at 7.2
Increase pH with some
pH+
Decrease pH with some
pH-
 Use some TAC+