Télécharger Imprimer la page

Tecnocontrol CITY CE424P Mode D'emploi page 77

Masquer les pouces Voir aussi pour CITY CE424P:

Publicité

Les langues disponibles

Les langues disponibles

IST-1424.CE02.02
If this procedure is correct, a window notifies you that the operation has
been successful. -----------------------------------------------------------------------
Then the screen returns to the selection of the type of configuration.
Configuring a GENERIC SENSOR: to proceed with the configuration,
press
on its line or simply the key
ENTER
Then, in the corresponding screen, with
numerical ones and then pressing
the sensor to be configured.---------------------------------------------------------
Then the model is set as GENERIC and it is possible, move on to setting of all parameters.
The parameters should be inserted similarly to the configuration of the Preconfigured Sensor.
In this case, however, you can also change the following items:
Description of the items relating to the Generic Sensor:
TYPE
It indicates the gas that the sensor will detect. You can choose between Flammab.
(Flammable), Toxic, Vital (e.g. Oxygen), Asphixian. (e.g. CO
(Refrigerant e.g. R134a).
It indicates the name of the gas for which the sensor has been calibrated. You can
GAS
choose between METHANE, LPG, PETROL (Petrol vapours), HYDROGEN, VARIOUS
(various gases), STYRENE, ACETYLENE, AMMONIA, CO, CO
HCN, OXYGEN, CL
It indicates the unit of measurement of the concentration detected by the sensor.
UoM
You can choose between %LEL (Lower Explosive Limit), %vol (Volume), ppm (parts per
million), ppb (parts per billion) and °C (temperature in degrees Celsius).
It shows the sensor's full scale. It consists of four digits and you can also set the
RANGE
decimal point. The numbers allowed, ranging from a minimum of 1, 0.1 or 0.01 up to
a maximum of 9999, 99.9 or 9.99. Other values or combinations are not accepted
and, if entered, will display the previous value
With the
and
e
or with the numerical ones and then press
The configurations of the full scale that use a number of digits less than 4 must be preceded by
a space
Example: To obtain a Range of 90 to enter space, space, 9, 0. Instead, the values space, 9, 0,
space or 9, 0, space, space, will not be accepted.
COPY (Level 2)
: This item allows you to copy the configuration of a
sensor to another sensor or group of sensors.
To copy a sensor, press
Then you enter the screen where pressing
keys or the numerical ones, you can choose which sensor to copy. ------
After pressing
again to confirm, you can use the
ENTER
choose whether to copy on a single sensor or in a group. -------------------
The first line acts on a single sensor. Pressing
be highlighted the number of the sensor.
Then press
and
desired number, then press
TECNOCONTROL S.r.l. - Via Miglioli, 47 20090 SEGRATE (MI) - Tel. 02. 26 92 28 90 - Fax 02. 21 33 734
CE424P / User Manual
2
.
you can choose the number of
ENTER
e HCL.
2
you can move from one digit to another, while you can change the value with
on its item or simply the key
ENTER
ENTER
keys or the numerical ones, to select the
will appear the confirmation window.
ENTER
and
key or with the
to confirm.
ENTER
4
.
and using
and
and
key,
on the first line, will
ENTER
Pag. 25/50
PRECONFIG. SENS.
SENSOR
N.
1
CONFIGURED
GENERIC SENSOR
1
SENSOR N.
is asphyxiating) and Refriger.
2
, H
S, NO, NO
, SO
2
2
2
COPY
1
SENSOR N.
COPY
1
SENSOR N.
ON
SENSOR N.
FROM N.
TO N.
,
2

Publicité