IST-1424.CE02.02
Pressing
on the first line, will highlight the number of the RU. Then
ENTER
you choose the desired number, with
keys and then pressing
Pressing
on the second line, will highlight the first RU's number of
ENTER
the group. --------------------------------------------------------------------------------
You can enable or disable all RU, including between two, both from the smallest to the largest
number, and the reverse, If the two numbers of sensors were equal, the effect is identical to
the management of a single RU.
With
and
or using the number keys, you can choose the
number of required RU, pressing
value to another and then, pressing
appear. -----------------------------------------------------------------------------------
Press again
to confirm or in case you want to go back, press
ENTER
If the RU is not configured, a window notifies you that the operation is not
possible. ----------------------------------------------------------------------------------
Then the screen returns to the selection of the RU.
If you have selected a group of RU, the ones that have been configured are enabled or
disable. Dialog box appears to warn you that you have selected one or more RU not configured.
If this procedure is correct, a window notifies you that the operation has
been successful. -----------------------------------------------------------------------
Then the screen returns to the beginning of the management for Enabled
or Disable the RU.
CONFIGURE (Level 2)
its item highlighted or simply press key
Then you can choose the RU's number to be configure, using
or the numeric key and pressing
With
and
you scroll through the various items and then
pressing
on the item, the value is highlighted to indicate that it is
ENTER
editable -----------------------------------------------------------------------------------
To change the value use
pressing
l the change will be accepted. Pressing
ENTER
the previous value and the entire row is selected, indicating that you can only scroll through the items.
Description of items related to the Remote Units:
REM.UNIT: indicates the number of the RU installed. This number corresponds to the RU that must
be set with the DIP-Switches (please see the specific RU manual).
The central unit considers configurable, the numbers of the sensors according to the number of
RU configured. The 1
24. The same concerns the relay outputs (if any), the 1
nd
no. 17, the 2
RU those from no.18 to 25.
PORT:
Sets the number of serial port which the RU is connected to. The control panel manages two
RS485serial ports, COM 1 and COM 2. Please enter the correct port number.
Please note that if the number of RU or the port is not correct, the RU will result out of line.
TECNOCONTROL S.r.l. - Via Miglioli, 47 20090 SEGRATE (MI) - Tel. 02. 26 92 28 90 - Fax 02. 21 33 734
CE424P / User Manual
and
the confirmation window will appear.
ENTER
and
ENTER
: To access the RU configuration, press
3
.
to confirm. ------------------------
ENTER
and
or the numeric keys. then
st
RU manages the sensors from no. 9 to 16, the 2
or using the numeric
you change from one
confirmation window will
ESC
ENTER
and
will restores
ESC
st
RU controls the relays from no. 10 to
Pag. 19/50
ABILITA
UN. REM N.
DAL N.
AL N.
ENABLE
CONFIRM ?
YES = ENTER
NO = ESC
ENABLE
.
REM. UNIT
N.
NOT CONF.
ENABLE
REM. UNIT
N.
1
on
ENABLED
CONFIG. REM.UNIT
REM. UNIT
CONFIG. REM.UNIT
REM. UNIT
PORT
SAVE
nd
RU those from 17 to
1
1
N.
N. 1
COM 1