If any errors occur during the upgrade, the firmware may be incomplete. This event will be
signaled by the message, FIRMWARE CORRUPT that appears when you restart the control
unit. In this case, try unpowered and restore power to the control unit and repeat the update.
If the problem persists, verify the integrity and correctness of the update file, loading the
previous working version of Firmware. Otherwise please contact our customer service.
COPY CONF. FROM (Livello 2)
configuration (Sensors, Logic Input, Zone, Remote Units and Outputs) of a control unit using a file previously
saved on the SD Card. The file, named "CE424_CF.txt", can ONLY be created using the "COPY
CONF. ON" (see below). This function can be used to restore a CE424 configuration (with memory
failure) or to transfer the same configuration on other CE424.
2
Press key
or
ENTER
display a brief explanation. ----------------------------------------------------------
In case of error or malfunction, the panel configuration will be
deleted. We recommend that you do not complete the table list
(See at the end of this manual).
After you have entered the SD card, press
updating the configuration or press
message appears, wait for. -----------------------------------------------------------
If the SD Card is not on file or can not be read, the display will show a
message, and then will reappear submenu SD Card. ------------------------
If an error occurs in the Read / Write or
if the file was corrupt, the panel will
report the error, will erase the current
configuration
and
then
normally to reload the configuration. -
If the result is correct, the panel will report
through a message and then will restart normally
to reload the configuration. ----------------------------
COPIA CONF. ON (Livello 2)
configuration (Sensors, Logic Input, Zone, Remote Units and Outputs) of the control unit into the SD Card.
The file, named "CE424_CF.txt", can ONLY be created using this
funtion. This file can be used as indicated above in the previous function.
3
Press key
or
ENTER
display a brief explanation. After you have insert the SD card, press the
to start saving configuration or press
ENTER
The sequence of operation described below is also valid for the
"Copy Events Up" and "Save Data".
When copying, a message appears, wait for. ------------------------------- ---
If the SD Card is not on file or can not be read, the display will show a
message, and then will reappear submenu SD Card. -----------------------
If the SD Card is not formatted or illegible, the panel will report through
a message and will return to the submenu SD Card. -------------------------
TECNOCONTROL S.r.l. - Via Miglioli, 47 20090 SEGRATE (MI) - Tel. 02. 26 92 28 90 - Fax 02. 21 33 734
CE424P / User Manual
: This item, "Copy Configuration From" allows you to load a
on its item, before you start the process will
ENTER
to go back. When copying a
ESC
ERROR
OPERATION
FAILED
will
restart
: This item, "Copy Configuration On" allows you to save the
on its item, before you start the process will
to go back. -----------------
ESC
to start copying and
CONFIGURATION
DELETED
OK
REBOOT IN
PROGRESS
Pag. 39/50
COPY CONF.
FROM
INSERT IN THE
CONTROL UNIT
THE SD CARD
AND PRESS ENTER
WAITING
ERROR
FILE MISSING
O
NOT READABLE
WAITING
REBOOT IN
PROGRESS
COPY CONF.
ON
INSERT IN THE
CONTROL UNIT
THE SD CARD
AND PRESS ENTER
WAITING
ERROR
SD CARD
PROTECTED
ERROR
SD CARD
NOT READABLE