2.4
CORRECT CONNECTION TO CHIMNEY
In picture 7 you can see some examples for a
correct connection of a wood fired thermal
cooker.
For a safe connection to the flue, we suggest
to use a double isolation of the wall. The
connection between the isolating material
and the flue must be well sealed.
It is very important that the connection be-
tween the thermal cooker and the flue is as
NO
Picture 7 - Examples of correct and uncorrect chimney hood connection
2.5
PREDISPOSITION OF THE EXHAUST-PIPE
ST 60 is endowed with the predisposition
for exhaust-pipe only on the top, rightwards
and leftwards. It is necessary to choose one
of them for use and to close the other one.
ST 90 and STK models are endowed with the
Picture 8 - Predisposition of the smoke outlet
short as possible. The connection must be
always placed horizontally or inclined up-
wards, never downwards. Bended or wind-
ing parts of pipe must be avoided.
The connection between the thermal cooker
and the flue must be well fixed and sealed.
The connections must not cross inflammable
or sensible to high temperatures furniture.
NO
NO
predisposition for the exhaust-pipe on the
top and in the rear, rightwards or leftwards.
In this case, the thermal cookers is given
with both the flue outlets covered. To con-
nect the thermal cooker you must modify
113