Process B. Correctly Select Your Pump
IMPORTANT: SELECT CORRECT VOLTAGE
Disconnect pump from power source before changing the pump
voltage. To change the voltage, the selector switch is located
underneath the plastic access cover on top of the motor. To
access the switch, remove the eight screws holding the plastic
cover. To change the voltage setting, slide the switch as shown
until desired voltage is visible on the switch. The voltage
number that appears is the voltage setting for the pump. Be sure
the switch is completely engaged. Replace the cover and secure
it with the eight screws.
VOLTAGE SELECTION DIRECTIONS
Warning!
Disconnect pump from your
source before servicing or
handling pump.
Be sure that incoming power
supply is same as voltage
115
selector switch setting.
To change voltage settings
slide switch as shown
until desired voltage is
230
visible on switch.
Be sure switch is completely
engaged.
Replace capacitor housing cover
and secure cover with screws.
Do not overtighten screws.
22700A375
WIRING CHART – RECOMMENDED WIRE AND FUSE SIZES
Motor
Model
HP
Volts
RTS5
1/2
115/230
RTS7
3/4
115/230
RTS10
1
115/230
RC5, RC5C
1/2
115/230
RC10, RC10C
1
115/230
115
230
Nameplate
Branch Fuse
Amps
Rating Amp
8.5/4.2
15/15
11.0/5.5
15/15
12.0/6.0
15/15
7.0/3.5
15/15
11.0/5.5
15/15
WIRING YOUR PUMP
Disconnect pump from power before servicing or handling pump.
Remove the cover from the pressure switch. Connect the bare
copper ground to the ground screw in the pressure switch.
Connect the power supply to the terminals marked "Line" in the
diagram below.
Ground
Connections
PIPING
Plastic PVC pipe is shown in the illustrations, but galvanized
steel pipe may be used if desired. All piping must be clean and
free of all foreign matter to prevent clogging. ALL JOINTS AND
CONNECTIONS IN THE WELL ASSEMBLY MUST BE AIRTIGHT. Even
a pinhole leak will prevent the proper operation of the pump
(this is the most common problem). Use thread compound on all
threaded joints unless specified otherwise.
DISTANCE IN FEET(METERS) FROM MOTOR TO SUPPLY
0 - 100
101 - 200
(0 - 30)
(31 - 61)
AWG WIRE SIZE (mm
14/14(2/2)
12/14(3/2)
14/14(2/2)
10/14(5.5/2)
14/14(2/2)
10/14(5.5/2)
14/14(2/2)
12/14(3/2)
14/14(2/2)
10/14(5.5/2)
3
To Motor
From Line
5907 1108
201 - 300
301 - 400
(62 - 91)
(92 - 122)
)
2
10/14(5.5/2)
8/14(8.4/2)
8/14(8.4/2)
6/14(14/2)
8/14(8.4/2)
6/14(14/2)
10/14(5.5/2)
10/14(5.5/2)
8/14(8.4/2)
6/14(14/2)