Generating Set Maintenance; Generating Set Identification; Changing The Engine Oil - SDMO PRO 2000 Manuel D'utilisation Et D'entretien

Masquer les pouces Voir aussi pour PRO 2000:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
4.8. Switching the generating set off
Always ensure that the generating set is suitably ventilated: the motor continues to give out heat after the
generating set has been shut down.
Ensure that the fuel tap and fuel tank vent are closed after each use.
IMPORTANT
Switch off and disconnect the devices used (A - 13 & A - 15).
Set the economy operation switch (A - 11) to the Hare position and allow the generating set to run without any load for a few
minutes.
Set the ON / OFF switch (A - 10) to the
Turn the fuel tap (A - 6) to the "OFF" position.
Close the fuel tank vent (A - 5) by turning it one complete revolution in a clockwise direction, whilst holding the fuel tank cap
(A - 4) tightly to prevent it from opening.

5. Generating set maintenance

5.1. Reminder of use
The maintenance operations to be carried out are detailed in the maintenance table. The interval for this is supplied as a guide and for
generating sets operating with fuel and oil which conform to the specifications given in this manual. Shorten the maintenance intervals
according to the conditions in which the generating set is used, and as required (for example, clean the air filter more frequently if the
generating set is used in dusty environments).
5.2. Maintenance intervals table
Component
Engine oil
Screen filter
Air filter
Spark plug
Spark arrester
Generating set
Valves
Breather
Combustion chamber
Fuel tank
5.3. Performing the maintenance operations

5.3.1 Changing the engine oil

To ensure that the oil service is performed quickly and correctly, the oil must be changed when the engine is warm (start the generating
set and allow it to run for a few minutes if necessary).
Observe the advice for protecting the environment (see § Guidelines for protecting the environment) and drain the oil into an
appropriate container.
Using a screwdriver, remove the screws (A - 23) and the side enclosure (A - 22).
Remove the oil filler cap (B - 1).
Position an appropriate container under the oil filler cap and tilt the generating set to allow the oil to flow out.
After all the oil has been drained out, reposition the generating set upright and use a funnel to top up with the recommended oil
(see § Specifications).
Refit the oil filler cap.
Check that there are no oil leaks, and wipe away any traces of oil with a clean cloth.
Close the side enclosure by tightening the mounting screws correctly.
position.
Operations to be
After
carried out at
whichever deadline is
or
reached first
Change
Clean
Check / Clean
Replace
Check / Clean
Check / Clean
Clean
Maintenance to be performed by one of our agents during the annual service.
Every
st
1
month
or
first 20 hours
Every
6 months
12 months
or
100 hours
300 hours

Publicité

Table des Matières
loading

Table des Matières