Gas Requi rements
the grill inlet pipe to avoid shifting any internal gas lines of the grill. Ensure that the regulator arrow
points in the direction of gas flow towards the unit, away from the supply. Do not forget to place the
installer supplied gas valve in an accessible location.
L.P. GAS HOOK UP (TYPE 1 OR QCC1 REGULATOR):
Grills orificed for use with L.P. gas come equipped with an high capacity hose/regulator assembly for
connection to a standard 20 lb. L.P. cylinder (Type 1).The L.P. tank is not included.
Connection: 1/2" NPT male with a 3/8" Flare adapter (included). LP Hose with a quick disconnect and
fittings are included. Operating pressure: 10.0"W.C.
To connect the L.P. regulator/hose assembly to the tank/valve assembly, first make sure the main valve on
the tank is completely closed. Although the flow of gas is stopped when the Type 1 system is discon-
nected as part of of its safety feature, you should always turn the L.P tank main valve (Fig.02) off after
each use and during transport of the tank or unit. Insert the regulator inlet into the tank valve and turn
to the black coupler clockwise until the coupler tightens up. Do not overtighten the coupler. Turn
the main tank valve on and turn the burner control valves on the unit to the "lite" position for about 20
seconds to allow the air in the system to purge before attempting to light the burners.
To disconnect the coupler, first make sure the main tank valve is turned off. Grasp the coupler and turn
counter clockwise. The inlet will then disengage, remove the inlet from the tank valve opening if it has
not already done so when it disengaged. Your local L.P. filling station should be equipped with the
proper equipment to fill your tank.
L.P.TANK REQUIREMENTS:
A dented or rusty L.P. tank may be hazardous and should be checked by your L.P. supplier. Never
use a cylinder with a damaged valve. Always check for leaks after every L.P. tank change.The L.P. gas
cylinder must be constructed and marked in accordance with the specifications for L.P. gas cylinders of the U.S.
Department of Transportation (DOT) and designed for use with a Type 1 system only. Do not change the
regulator/hose assembly from that supplied with the unit or attempt to use a 5LP-A equipped regulator/hose
assembly with a standard 510 POL tank/valve assembly. The cylinder must be provided with a shut off valve
terminating in an L.P. gas supply cylinder valve outlet specified, as applicable, for connection Type 1. If the
appliance is stored indoors the cylinder must be disconnected and removed from the appliance.
Cylinders must be stored outdoors in a well-ventilated area out of the reach of children.
FIG.02 L.P. Gas (36BQR Shown)