ERMO
Mounting position, vertical or diagonal
WARNING
Uncontrolled payload if there is a power failure.
Injury due to electric shock, impact, or pinching.
• For eccentric attachment components, use only motors with holding brake.
• Check whether safety measures are required to prevent falling (e.g. toothed latches,
bolts or emergency buffer).
Take appropriate measures, if necessary.
5.1.1

Mount drive

Requirements
• Place the product in such a way that its control sections are accessible (e.g. proximity sensors).
Interfaces for mounting components to the profile
On the side
Fig. 2
• Select mounting components or accessories (è www.festo.com/catalogue).
• Make sure that mounting components are outside the positioning range.
• Fasten the drive.
• Tighten screws evenly.
Size
Screw
Tightening torque
Centring hole
Max. screw-in depth
(Side mounting)
Tab. 1
Festo – ERMO – 1505NH English
From the front/rear
12
M4
[Nm]
3
@7H7
[mm]
[mm]
7
16
25
M5
M6
5
8
@7H7
@9H7
8
9.5
32
M8
24
@12H7
15
21