Télécharger Imprimer la page

Dimplex WPM EconPlus Instructions De Montage Et De Service page 59

Masquer les pouces Voir aussi pour WPM EconPlus:

Publicité

Configuring the Heat Pump Heating System
System-specific parameters
For each day of the week, it is possible to select
whether Time1, Time2, no time or both times
are to be active when the temperature is
lowered. Operations to lower the temperature
that exceed a weekday are activated or
deactivated at the end of each day accordingly.
All settings to raise the heating characteristic
curve of heating circuit 2/3
Sets the time during which the temperature in
heating circuit 2/3 is to be raised.
Sets the temperature value by which the
heating characteristic curve of heating circuit 2/
3 is to be raised when the temperature is
raised.
For each day of the week, it is possible to select
whether Time1, Time2, no time or both times
are to be active when the temperature is raised.
Operations to raise the temperature that
exceed a week day are activated or deactivated
at the end of each day accordingly.
Settings for cooling operation
Does the system have dynamic cooling (fixed
return set temperature)?
Sets the desired return flow set temperature
when dynamic cooling is selected
Does the system have silent (dew point-
controlled) cooling?
Sets the room set temperature for silent
cooling.
The actual value is measured by room climate
control station 1
Raises the minimum permissible flow
temperature calculated from the measured
values from room climate control station 1. A
raised value reduces the risk of condensate
forming.
Does the system have additional silent (dew
point-controlled) cooling?
Sets the room set temperature for silent
cooling.
The actual value is measured by room climate
control station 2.
Raises the minimum permissible flow
temperature calculated from the measured
values from room climate control station 2. A
raised value reduces the risk of condensate
forming.
Sets the time programs for dynamic cooling
Sets the times during which dynamic cooling is
blocked.
Setting range
Display
N
Heating circuit 2
and 3
T1
T2
Y
Heating circuit 2
and 3
00:00
Heating circuit 2
and 3
...
23:59
0K
Heating circuit 2
and 3
...
19K
N
Heating circuit 2
and 3
T1
T2
Y
Cooling function
No
Cooling function
Yes
10 °C
Cooling function
... 15 °C ...
Dyn. cooling
30 °C
Yes
Cooling function
No
15.0 °C
Cooling function
... 20.0 °C ...
Silent cooling, HC2
30.0 °C
1,5K
Cooling function
...3,5K...
Silent cooling, HC2
5K
No
Cooling function
Yes
Silent cooling, HC2
Heating circuit 3
15°C
Cooling function
...20°C...
Silent cooling, HC2
30°C
Silent cooling, HC3
1,5K
Cooling function
...3,5K...
Silent cooling, HC2
5K
Silent cooling, HC3
Cooling function
Dyn. cooling
00:00
Cooling function
...
Dyn. cooling
23:59
6.1
EN-15

Publicité

loading

Ce manuel est également adapté pour:

Wpm econrWpm econplus-e452114.66.58