6.2
Device and sensor settings
Name:
Device settings:
Password(s)
Acoustic operation signal
Switch-off mode
Short-term exposure limit
1)2)
(STEL)
3)
Shift length (TWA)
Alarm thresholds configura-
4)
tion type
Sensor settings:
A1 alarm:
Latching
Acknowledgeable
A2 alarm:
Acknowledgeable
Alarm threshold A1 increas-
ing (in measurement module)
Alarm threshold A2 increas-
ing (in measurement module)
Alarm threshold A1 decreas-
ing
(in measurement module,
only O
sensors)
2
Alarm threshold A2 decreas-
ing
(in measurement module,
only O
sensors)
2
1)
Evaluation type
Alarm threshold STEL (in
1)
measurement module)
Alarm threshold TWA (in
1)
measurement module)
1) Evaluated only if the sensor is intended for this purpose.
2) Corresponds to the averaging time and is used to calculate the STEL
exposure level.
3) Corresponds to the averaging time and is used to calculate the TWA
exposure level.
4) The deactivation of the ATEX-conformity leads to the loss of the tech-
nical suitability test.
Instructions for use
|
X-am
Area / setting
Numerical range (4-digit)
Yes / No
"Switch off allowed" or
"Switch off forbidden" or
"Switch off forbidden in A2"
0 - 60 (in minutes; setting for
exposure alarm)
60 - 1440 (in minutes, setting
for exposure alarm)
ATEX-conformity/extended
On/off
On/off
On/off
0 to A2
A1 to full scale deflection
A2 decreasing to A1 increas-
ing
0 to A1 decreasing
Inactive TWA, STEL,
TWA+STEL
0 – full scale deflection
0 – full scale deflection
®