Device Settings; Factory Settings - Dräger X-am 3500 Notice D'utilisation

Masquer les pouces Voir aussi pour X-am 3500:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 44
en
|

Device settings

Designation and descrip-
tion
Plug-in power supply unit
100-240 V AC; 1.33 A for
charging up to 5 gas detec-
tors
(requires adapter 83 25 736)
Plug-in power supply unit
100-240 V AC; 6.25 A for
charging up to 20 gas detec-
tors
(requires adapter 83 25 736)
Vehicle connection
12 V / 24 V for charging
1 gas detector
Vehicle connection 12 V / 24
V for charging up to 5 gas
detectors
(requires adapter 83 25 736)
Vehicle mount
(requires adapter 83 25 736
and vehicle connection cable
83 21 855)
5.7
Cleaning
The gas detector does not require any special care.
If it is heavily soiled, wash the gas detector with cold water
and use a sponge if necessary. Dry the gas detector with a
cloth.
NOTICE
Damage to the gas detector!
Harsh cleaning utensils (e.g. brushes), detergents and
solvents can destroy the dust and water filters.
► Only clean the gas detector with cold water and, where
necessary, a sponge.
► If the gas inlets are protected by the pump adapter, then a
soft brush can also be used to clean the device. After
cleaning, make sure that the gas inlet is free.
The shoulder strap can be cleaned with water and without
cleaning agents in a wash bag in an (industrial) washing
machine.
For information on suitable cleaning agents and disin-
fectants and their specifications, see document
9100081 at www.draeger.com/IFU.
6
Device settings
Only trained and qualified personnel may change the device
settings.
For more details, refer to the technical manual.
40
6.1
Order no.
Different settings can be selected to meet customer
requirements on order. The setting can be checked and
83 21 849
changed with the Dräger CC-Vision PC software.
gas detector after transmission to ensure that the values were
transmitted correctly.
83 21 850
Parameters that cannot be viewed on the gas detector must
be exported using the Dräger CC-Vision PC software after a
change and checked.
Function
45 30 057
Fresh air calibration without
password
Bump test without password
83 21 855
Operation signal
Switch off allowed
Capture range
83 27 636
LEL factor
ch4 (methane)
H
STEL
TWA
Alarm thresholds configura-
tion type
Alarm A1
Alarm A2
Symbol for type of danger
Expired bump test interval
Expired calibration interval
Power-save mode display
1) The set capture range can be read on the gas detector and can be
2) An LEL factor can be adapted to national regulations using the Dräger

Factory settings

The modified parameter settings must be checked on the
1)
2)
(hydrogen)
2
activated and deactivated. The capture range is activated in measur-
ing mode by default. The capture range is always deactivated in cali-
bration mode.
CC-Vision PC software.
Instructions for use
Setting
On
Off
On
On
On
4.4 Vol% (corresponds to
100 %LEL)
4.0 Vol% (corresponds to
100 %LEL)
STEL feature – inactive;
average duration =
15 minutes
TWA feature – inactive; aver-
age duration = 8 hours
ATEX-compliant
Acknowledgeable, non-latch-
ing, pre-alarm, increasing
measured value (for O
sen-
2
sors, decreasing measured
value as well)
Non-acknowledgeable, latch-
ing, main alarm, increasing
measured value (for O
sen-
2
sors, decreasing measured
value as well)
On
Warning
Channel warning
Off
®
|
X-am
3500