The following addresses are only displayed when the
linearisation points (
linearisation points 1 to 32 are identical.
The entry sequence of the linearisation points is random.
The sensor values (X-Value) are automatically sorted
upwards before they are saved.
Unused points, sensor value is identical “
automatically deleted and the number of points respectively
lowered in number.
If points are to be added later then the value under
must be increased to the required number. The new
addresses will be added before the last value. The remaining
linearisation points should be entered in the new addresses.
This again is independent from sequence. The added values
will again be sorted upwards automatically before being saved.
arameter
* Sensor values
Input of sensor value of
the analogue input in
engineering units
(X-value)
In order to delete the linearisation point the value “
Keep the push button “+” held down until the value appears
* Display value
Input of the sensor value
allocated display value
(Y-value)
5.7 Service parameters
arameter
Service Code
Operation address for the
customer service
parameter release code
) are active (
LSHOW
Setting up selections
1
32
to
Value:
Sensor scale 0%
Sc LO
(
)
to
Sensor scale 100%
Sc HI
(
)
Y1
Y32
to
Value:
-19999 to 99999
Setting up selections
SCODE
). Addresses for
YES
”, are
-----
COUNT
Default
settings
-----
-----
” can be set up
00000
Default
settings
-----
Process transmitter
to
NO1
NO32
Actual
setting
SERV
Actual
setting
67