Adjusting The Inductive Proximity Switch (Option) - Burkert 8630 Instructions De Service

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5.5

Adjusting the inductive proximity switch (option)

ATTENTION!
It is necessary to open the Top Control housing to install the inductive proximity switch.
Disconnect the power supply before opening open the Top Control .
Opening the Top Control :
Remove the screws and possible seals between the cover and the housing.
Twist the cover to the left and remove it.
Installing the inductive proximity switch:
Mount each inductive proximity switch at the top over the fixing screws. (Fig. 5.4):
Turn right ensures
adjustment
to the top
Bild 5.5: Setting of the inductive proximity switch with the setscrews
116
Turn left ensures
adjustment
to the top
Fixing for upper position
switch
Fixing for lower position
switch
Operating instructions no. 800607

Publicité

Table des Matières
loading

Table des Matières