Do not operate the product in explosion-hazard areas.
Sterilize product before use.
When using the ECCOS fixation system, adhere to the appropriate
instructions for use for TA009721, see Aesculap Extranet at
https://extranet.bbraun.com
4.
Product description
4.1
Scope of supply
Art. no.
Designation
GA340
Dermatome
– or –
GA341
Dermatome 0.1 mm
GA678
Sterile funnel
TA014549
Instructions for use of Dermatome GA340/GA341
(flyer)
4.2
Components required for operation
Li-Ion battery short GA346 (charged)
Sterile funnel GA678
Lid GA675
Dermatome blade GB228R
4.3
Operating principle
The product 1 contains an electric motor, which is powered by a replace-
able battery 7.
The charged non-sterile battery 7 is inserted into the product 1 via the
sterile funnel 6 and sealed with the lid 8 so that it is sterile.
The product moves the dermatome blade 11 in oscillation. The oscillation
frequency is controlled electronically and can be continuously regulated
with the trigger 2.
5.
Preparation
Aesculap assumes no liability if the following rules are not followed:
Do not use products from open or damaged sterile packaging.
Prior to use, inspect the product and its accessories for any visible
damage.
Use the products and their accessories only if they are in perfect tech-
nical condition.
6.
Working with the device
Risk of infection and contamination!
Product is delivered unsterilized!
WARNING
Sterilize the product before use pursuant to the
operating instructions.
Risk of injury and material damage due to acciden-
tal activation of the product!
Products which are not being actively used must
WARNING
be secured against accidental activation (posi-
tion OFF).
Risk of injury and material damage due to inappro-
priate use of tools!
WARNING
Always follow the safety advice and information
given in the instructions for use.
When coupling/uncoupling, handle tools with
cutting edges with care.
Damage to the product if dropped!
Use the products only if they are in perfect
technical condition, see Function check
WARNING
Risk of injury and/or malfunction due to unrecog-
nized change to cutting setting!
The basic adjustment of the cutting setting can
WARNING
change if the product falls on the floor, for exam-
ple.
Do not use product.
Have the manufacturer inspect the product.
Risk of burns to skin and tissue through blunt tools
or if product has not been maintained properly!
Use tools only if they are in perfect condition.
WARNING
Replace blunt tools.
Maintain the product properly, see maintenance
guide.
5