Proservo NMS80
Entrée
Réglage usine
Information
supplémentaire
Density value
Navigation
Description
Information
supplémentaire
Minimum level
Navigation
Description
Entrée
Réglage usine
Information
supplémentaire
Minimum pressure
Navigation
Description
Entrée
Réglage usine
Endress+Hauser
0 ... 3 000 kg/m³
800 kg/m³
Accès en lecture
Accès en écriture
Setup → Advanced setup → Application → Tank calculation → HTMS → Density value
Shows the calculated product density.
Accès en lecture
Accès en écriture
Setup → Advanced setup → Application → Tank calculation → HTMS → Minimum
level
Defines the minimum product level for a HTMS calculation. If Lp - V falls below the limit
defined in this parameter, the density retains its last value or the manual value is used
instead.
0 ... 20 000 mm
7 000 mm
Accès en lecture
Accès en écriture
Setup → Advanced setup → Application → Tank calculation → HTMS → Minimum
pressure
Defines the minimum pressure for a HTMS calculation. If the pressure P1 falls below the
limit defined in this parameter, the density retains its last value or the manual value is
used instead.
0 ... 100 bar
0,1 bar
Maintenance
Maintenance
Operator
-
Operator
Maintenance
Menu de configuration
279