Diagnostic et suppression des défauts
142
Numéro de
Texte court
diagnostic
334
System recovery failure
381
Displacer distance invalid
382
Sensor communication
Diagnostic de la configuration
400
AIO simulation output
401
DIO simulation output
403
Calibration AIO
404
Calibration AIP
405
COMM timeout DIO 1 ... 8
406
IOM offline
407
COMM timeout AIO 1 ... 2
408
Invalid range AIO 1 ... 2
409
RTD temp out of range 1 ... 2 1. Check electronic modules
410
Data transfer
411
Hart device 1 ... 15 has
malfunction
412
Processing download
413
NMT 1 ... 15: element is
open or short
415
Hart device 1 ... 15 offline
434
Real time clock defective
436
Date/Time incorrect
437
Configuration incompatible
438
Dataset
441
AIO 1 ... 2 current output
alarm
Mesures correctives
HW changed, system recovery
failure. Return to factory
1. Calibrate sensor
2. Restart device
3. Replace sensor electronics
1. Check connection of sensor
electronics
2. Restart device
3. Replace sensor electronics
Deactivate simulation AIO
output
Deactivate simulation DIO
output
1. Restart device
2. Change I/O module
1. Restart device
2. Change I/O module
1. Check wiring
2. Change I/O module
1. Check wiring
2. Change I/O module
1. Check wiring
2. Change I/O module
1. Check device configuration.
2. Check wiring.
2. Change I/O or main
electronic module
1. Check connection
2. Retry data transfer
1. Check HART device
2. Change HART device
Download active, please wait
1. Check NMT wiring
connection
2. Replace NMT
1. Check HART device
2. Change HART device
Replace main electronics
Check date and time settings.
1. Restart device
2. Contact service
1. Check data set file
2. Check device configuration
3. Up- and download new
configuration
1. Check process
2. Check current output
settings
Proservo NMS80
Signal
Comportement du
d'état
diagnostic
[au
[au départ usine]
départ
usine]
F
Alarm
F
Alarm
F
Alarm
C
Warning
C
Warning
F
Alarm
F
Alarm
F
Alarm
F
Alarm
F
Alarm
C
Warning
C
Warning
F
Alarm
1)
F
Alarm
C
Warning
C
Warning
C
Warning
C
Warning
M
Warning
F
Alarm
M
Warning
F
Alarm