Commissioning
Code
No.
Name
Serial baud rate
Frequency setpoint via
keys
or Modbus
Start condition
(with mains on)
Flying restart selection
Motor auto-calibration
6
Mode selection for c61
1
Present status/error
Last error
Last error but one
Last error but two
18
Possible Settings
Lenze Selection
0
0 LECOM: 9600 bps
Modbus: 9600,8,N,2
1 LECOM: 4800 bps
Modbus: 9600,8,N,1
2 LECOM: 2400 bps
Modbus: 9600,8,E,1
3 LECOM: 1200 bps
Modbus: 9600,8,O,1
0.0
0.0
{Hz}
1
0
Start after LOW-HIGH
change at terminal 28
1
Auto start if terminal 28 = HIGH
2
Flying restart (auto start disabled)
3
Auto start if terminal 28 = HIGH,
with flying restart
WARNING!
Automatic starting/restarting may cause damage to equipment and/or injury to personnel!
Automatic starting/restarting should only be used on equipment that is inaccessible to
personnel.
0
0
Search range: C11...0 Hz
1
Search range: last frequency...0 Hz
0
0
Calibration not done
1
Calibration enabled
2
Calibration complete
0
0
Monitoring only
1
Monitoring and editing
status/error message
error message
ENGLISH
IMPORTANT
• See C01
• LECOM if C01 = 0...3
• Modbus if C01 = 8...11
240
Only active if C01 is set properly
(C01 = 1, 5, 7, 9, 11)
See also c43 and c70
If c42 = 2 or 3, the controller will start the
motor speed search at C11, or at the last
output frequency before the fault, depending
on the setting of c43
• If C14 = 4...7, motor calibration must
be performed, but C86...C91 must be
programmed first (see C14)
• If motor calibration is attempted before
programming C86...C91, triggers
fault
c60 = 1 allows the keys
speed setpoint (c40) while monitoring c61
• Display
• Refer to Section 5 for explanation of status
and error messages
to adjust