Commissioning
4.3

Parameter menu

Code
No.
Name
Password entry
1
Setpoint and control
source
Load Lenze setting
12
Possible Settings
Lenze Selection
0
0
0
Setpoint source:
0
Analog input (8U / 8I; see C34)
1
Code c40 / Code C47
2
Analog input (8U / 8I; see C34)
3
LECOM
4
Analog input (8U / 8I; see C34)
5
Code c40 / Code C47
6
Analog input (8U / 8I; see C34)
7
Code c40 / Code C47
8
Analog input (8U / 8I; see C34)
9
Code c40 / Code C47
10 Analog input (8U / 8I; see C34)
11 Code c40 / Code C47
Note
• When C01 = 1, 5, 7, 9, or 11 and C14 = 0...4, 6, 7, use c40 for speed setpoint
• When C01 = 1, 5, 7, 9, or 11 and C14 = 5, use C47 for torque setpoint
• When C01 = LECOM (3), write speed command to C46 or torque command to C47.
0
No action/loading complete
1
Load 50 Hz Lenze settings
2
Load 60 Hz Lenze settings
3
Load OEM settings (if present)
WARNING!
C02 = 1...3 overwrites all settings! TRIP circuitry may be disabled!
Check codes CE1...CE4.
ENGLISH
IMPORTANT
999
Visible only when password is active
(see C94)
Control configuration:
Control = terminals
Programming = keypad
Monitoring = LECOM
Control = terminals
Programming = LECOM / keypad
Monitoring = LECOM
Control = LECOM
Programming = LECOM / keypad
Monitoring = LECOM
Control = terminals
Programming = remote keypad
Monitoring = remote keypad
Control = remote keypad
Programming = remote keypad
Monitoring = remote keypad
Control = terminals
Programming = Modbus / keypad
Monitoring = Modbus
Control = Modbus
Programming = Modbus / keypad
Monitoring = Modbus
• C02 = 1, 2, 3 only possible with
or
• C02 = 2 : C11, C15 and C89 = 60 Hz
and C87 = 1750RPM