Description des paramètres
13-43 Logic Rule Operator 2
Tableau [6]
Option:
3
3
[0]
DISABLED
*
[1]
AND
[2]
OR
[3]
AND NOT
[4]
OR NOT
[5]
NOT AND
[6]
NOT OR
[7]
NOT AND NOT
[8]
NOT OR NOT
13-44 Logic Rule Boolean 3
Tableau [6]
Option:
[0]
False
*
[1]
True
[2]
Running
[3]
In range
[4]
On reference
[5]
Torque limit
[6]
Current limit
[7]
Out of current range
[8]
Below I low
[9]
Above I high
[10]
Out of speed range
[11]
Below speed low
[12]
Above speed high
[13]
Out of feedb. range
[14]
Below feedb. low
[15]
Above feedb. high
[16]
Thermal warning
[17]
Mains out of range
[18]
Reversing
142
Guide de programmation du FC 300
Fonction:
Sélectionner le second opérateur logique à
utiliser sur l'entrée booléenne calculée aux
13-40 Logic Rule Boolean 1, 13-41 Logic Rule
Operator 1 et 13-42 Logic Rule Boolean 2 et
l'entrée booléenne du 13-42 Logic Rule
Boolean 2.
[13-44] correspond à l'entrée booléenne du
13-44 Logic Rule Boolean 3.
[13-40/13-42] correspond à l'entrée
booléenne calculée aux 13-40 Logic Rule
Boolean 1, 13-41 Logic Rule Operator 1 et
13-42 Logic Rule Boolean 2. DÉSACTIVÉ [0]
(réglage d'usine) : sélectionner cette option
pour ignorer le 13-44 Logic Rule Boolean 3.
Fonction:
Sélectionner la troisième entrée
booléenne (VRAI ou FAUX) pour la
règle logique sélectionnée. Voir le
13-01 Start Event ([0]-[61]) et le
13-02 Stop Event ([70]-[75]) pour
une description détaillée.
MG33MD04 - VLT
13-44 Logic Rule Boolean 3
Tableau [6]
Option:
[19]
Warning
[20]
Alarm (trip)
[21]
Alarm (trip lock)
[22]
Comparator 0
[23]
Comparator 1
[24]
Comparator 2
[25]
Comparator 3
[26]
Logic rule 0
[27]
Logic rule 1
[28]
Logic rule 2
[29]
Logic rule 3
[30]
SL Time-out 0
[31]
SL Time-out 1
[32]
SL Time-out 2
[33]
Digital input DI18
[34]
Digital input DI19
[35]
Digital input DI27
[36]
Digital input DI29
[37]
Digital input DI32
[38]
Digital input DI33
[39]
Start command
[40]
Drive stopped
[41]
Reset Trip
[42]
Auto-reset Trip
[43]
Ok key
[44]
Reset key
[45]
Left key
[46]
Right key
[47]
Up key
[48]
Down key
[50]
Comparator 4
[51]
Comparator 5
[60]
Logic rule 4
[61]
Logic rule 5
[70]
SL Time-out 3
[71]
SL Time-out 4
[72]
SL Time-out 5
[73]
SL Time-out 6
[74]
SL Time-out 7
[75]
Start command given
[76]
Digital input x30/2
[77]
Digital input x30/3
[78]
Digital input x30/4
[79]
Digital input x46/1
[80]
Digital input x46/3
[81]
Digital input x46/5
[82]
Digital input x46/7
[83]
Digital input x46/9
[84]
Digital input x46/11
[85]
Digital input x46/13
®