Danfoss VLT Guide De Programmation page 142

Automationdrive
Masquer les pouces Voir aussi pour VLT:
Table des Matières

Publicité

Description des paramètres
13-42 Logic Rule Boolean 2
Tableau [6]
Option:
[1]
True
[2]
Running
[3]
In range
[4]
On reference
[5]
Torque limit
[6]
Current limit
[7]
Out of current range
[8]
Below I low
[9]
Above I high
[10]
Out of speed range
[11]
Below speed low
[12]
Above speed high
[13]
Out of feedb. range
[14]
Below feedb. low
[15]
Above feedb. high
[16]
Thermal warning
[17]
Mains out of range
[18]
Reversing
[19]
Warning
[20]
Alarm (trip)
[21]
Alarm (trip lock)
[22]
Comparator 0
[23]
Comparator 1
[24]
Comparator 2
[25]
Comparator 3
[26]
Logic rule 0
[27]
Logic rule 1
[28]
Logic rule 2
[29]
Logic rule 3
[30]
SL Time-out 0
[31]
SL Time-out 1
[32]
SL Time-out 2
[33]
Digital input DI18
[34]
Digital input DI19
[35]
Digital input DI27
[36]
Digital input DI29
[37]
Digital input DI32
[38]
Digital input DI33
[39]
Start command
[40]
Drive stopped
[41]
Reset Trip
[42]
Auto-reset Trip
[43]
Ok key
[44]
Reset key
[45]
Left key
[46]
Right key
[47]
Up key
[48]
Down key
Guide de programmation du FC 300
Fonction:
13-01 Start Event ([0]-[61]) et le
13-02 Stop Event ([70]-[75]) pour
une description détaillée.
®
MG33MD04 - VLT
est une marque déposée Danfoss
13-42 Logic Rule Boolean 2
Tableau [6]
Option:
Fonction:
[50]
Comparator 4
[51]
Comparator 5
[60]
Logic rule 4
[61]
Logic rule 5
[70]
SL Time-out 3
[71]
SL Time-out 4
[72]
SL Time-out 5
[73]
SL Time-out 6
[74]
SL Time-out 7
[75]
Start command given
[76]
Digital input x30/2
[77]
Digital input x30/3
[78]
Digital input x30/4
[79]
Digital input x46/1
[80]
Digital input x46/3
[81]
Digital input x46/5
[82]
Digital input x46/7
[83]
Digital input x46/9
[84]
Digital input x46/11
[85]
Digital input x46/13
[90]
ATEX ETR cur. warning
Sélectionnable si 1-90 Motor
Thermal Protection est réglé sur
[20] ou [21]. Si l'alarme 164
Alarme lim. courant ETR ATEX est
active, la sortie sera 1.
[91]
ATEX ETR cur. alarm
Sélectionnable si 1-90 Motor
Thermal Protection est réglé sur
[20] ou [21]. Si l'alarme 166
Alarme lim. fréq. ETR ATEX est
active, la sortie sera 1.
[92]
ATEX ETR freq. warning Sélectionnable si 1-90 Motor
Thermal Protection est réglé sur
[20] ou [21]. Si l'alarme 163
Avertissement lim. courant ETR
ATEX est actif, la sortie sera 1.
[93]
ATEX ETR freq. alarm
Sélectionnable si 1-90 Motor
Thermal Protection est réglé sur
[20] ou [21]. Si l'avertissement 165
Avertissement lim. fréq. ETR ATEX
est actif, la sortie sera 1.
[94]
RS Flipflop 0
[95]
RS Flipflop 1
[96]
RS Flipflop 2
[97]
RS Flipflop 3
[98]
RS Flipflop 4
[99]
RS Flipflop 5
[100] RS Flipflop 6
[101] RS Flipflop 7
3
3
141

Publicité

Table des Matières
loading

Table des Matières