Fault Correction - Franke AQUALINE-Therm AQLT0053 Notice De Montage Et De Mise En Service

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

20. Adjusting the Key Stroke
20.1 Remove the cover plate (a).
20.2 If the key has too much play, turn the screw (b) clockwise.
20.3 If water flows continuously, turn the screw (b) counter-clockwise.
20.4 Trigger the fitting.
20.5 Check the flow duration and correct if necessary (see

21. Fault Correction

Fault
Water does not flow
Flow duration too
short or too long
Water flows continu-
ously
Water is too hot
Water is too cold
Water flow too weak – Water volume regulator is not fully
Thermostat not
consistently
controlling
Cause
– Water supply interrupted
– Water-flow volume regulator closed ➯ Open it
– Functional part faulty
– Grit filters/Non-return valve dirty
– Key stroke is incorrectly adjusted
– Flow duration setting incorrect
– Functional part faulty
– Functional part faulty
– Flow volume regulator in shower
head calcified
– Key stroke is incorrectly adjusted
– Scald-protector incorrectly set
– Thermocouple faulty
– Scald-protector incorrectly set
– Hot water is turned off
– Grit filters/Non-return valve dirty
– Hot water supply pressure too low
– Hot water temperature too low
– Thermocouple faulty
opened
– Shower head calcified
– Grit filters/Non-return valve dirty
– Supply pressure too low
– Shower head defective
– Thermocouple dirty
Chapter
13.).
Remedy
➯ Restore it
➯ Replace it
➯ Clean, replace if necessary
➯ Adjust it
➯ Adjust it
➯ Replace it
➯ Replace it
➯ Clean, replace if
necessary
➯ Adjust it
➯ Adjust it
➯ Replace it
➯ Adjust it
➯ Open it
➯ Clean, replace if
necessary
➯ Check it
➯ Increase it
➯ Replace it
➯ Open it
➯ Clean it
➯ Clean, replace if
necessary
➯ Check it
➯ Replace it
➯ Clean it
11

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

2000110494

Table des Matières