13. Fault correction

Fault
Water does not flow at
all
Water flows
continuously
Water flow too weak
Water flow too large
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform the AQUA service department.

14. Replacement parts

Omschrijving
1 Remote activation valve . . . . . . . . 2000104780
2 Cover plate . . . . . . . . . . . . . . . . . . 2000105589
3 Safety screw (2 pcs.). . . . . . . . . . . 2000104700
4 WC flush valve
2000100074, 2030008823. . . . 2000104835
2000100075. . . . . . . . . . . . . . . 2000104830
4a Upper section
2000100074, 2030008823. . . . 2000104389
2000100075. . . . . . . . . . . . . . . 2000104384
5 Complete screw connections
2000100074, 2030008823. . . . 2000106164
2000100075. . . . . . . . . . . . . . . 2000104904
6 Remote activation hose. . . . . . . . . 2000104803
Replacement parts set for DN 20 consisting of:
Rubber parts
Spring
Seals . . . . . . . . . . . . . . . . . . . . 2000104867
Cause
– Stop valve or flow volume regulator-
closed.
– Upper section faulty
– Activation valve faulty
– Upper section faulty
– Activation valve faulty
– Stop valve or flow volume regulator-
not fully opened.
– Supply pressure too low
– Flush volume adjustment incorrect
– Flush volume adjustment incorrect
Bestelnr.
Remedy
➯ Open it
➯ Replace it
➯ Replace it
➯ Replace it
➯ Replace it
➯ Open it
➯ Check it
➯ Adjust it
➯ Adjust it
7