Fault Correction - Franke AQUALINE AQLT0085 Notice De Montage Et De Mise En Service

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

22. Fault Correction

Fault
Water does not flow
Flow duration too
short or too long
Water flows continu-
ously
Water is too hot
Water is too cold
Water flow too weak
Thermostat not
constant
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform our customer service department!
12
Cause
– Water supply interrupted
– Water-flow volume regulator closed ➯ Open it
– Functional part faulty
– Grit filters/Non-return valve dirty
– Key stroke is incorrectly adjusted
– Flow duration setting incorrect
– Functional part faulty
– Aerator calcified
– Functional part faulty
– Flow volume regulator in shower
head is calcified
– Key stroke is incorrectly adjusted
– Scald-protector incorrectly set
– Cold water is turned off
– Thermocouple faulty
– Scald-protector incorrectly set
– Hot water is turned off
– Grit filters/Non-return valve dirty
– Hot water supply pressure too low
– Hot water temperature too low
– Thermocouple faulty
– Water volume regulator is not fully
opened
– Aerator calcified
– Grit filters/Non-return valve dirty
– Supply pressure too low
– Thermocouple dirty
Remedy
➯ Restore it
➯ Replace it
➯ Clean, replace if
necessary
➯ Adjust it
➯ Adjust it
➯ Replace it
➯ Clean it
➯ Replace it
➯ Clean, replace if
necessary
➯ Adjust it
➯ Adjust it
➯ Open it
➯ Replace it
➯ Adjust it
➯ Open it
➯ Clean, replace if
necessary
➯ Check it
➯ Increase it
➯ Replace it
➯ Open it
➯ Clean it
➯ Clean, replace if
necessary
➯ Check it
➯ Clean it

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Aqualine aqlt008620300085262030008527

Table des Matières