Replacing The Grit Filters; Fault Correction - Franke AQCT0043 Notice De Montage Et De Mise En Service

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12

17. Replacing the Grit Filters

Filter for water volume regulator
17.1 Remove the cover plate (see
17.2 Screw the locking screw (a) on the flow volume regulator.
17.3 Replace the filter (b).
Important!
Ensure that the filter is positioned correctly.
17.4 Reassemble in the reverse order.
Filter for solenoid valve
17.5 Remove the cover plate (see
17.6 Dismount the solenoid valve (d).
17.7 Replace the filter (c).
Important!
Ensure that the filter is positioned correctly.
Important!
The solenoid valve must be connected before the power supply.
17.8 Reassemble in the reverse order.

18. Fault Correction

Fault
Water does not flow
Water flows continu-
ously
Water flow too weak
Flow duration too
short or too long
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform our customer service department!
10
Chapter
16.).
Chapter
16.).
Cause
– Stop valve is closed
– Voltage supply interrupted
– Sensor faulty
– Solenoid valve faulty
– Solenoid valve dirty
– Solenoid valve faulty
– Supply pressure too low
– Grit filter is clogged
– Water volume regulator is not fully
opened
– Aerator calcified
– Incorrect settings
– Electronic module defective
Remedy
➯ Open it
➯ Restore it
➯ Replace it
➯ Replace it
➯ Clean it
➯ Replace it
➯ Check it
➯ Clean it
➯ Open it
➯ Clean it
➯ Adjust it
➯ Replace it