Fault Correction; Replacement Parts - Franke 2338 10 23 Notice De Montage Et De Mise En Service

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

11.5 Remove the pressure cap and the spring.
11.6 Use a socket spanner to remove the functional part.
11.7 Reassemble in the reverse order.
11.8 Check the flow duration and correct if necessary (see

12. Fault Correction

Fault
Valve does not open
Valve does not close
Water flow too weak
Flow duration too
short or too long
If you are unable to correct a fault, or if the fault is not described in the table, please
inform the customer service department.

13. Replacement Parts

Designation
1 Pressure cap. . . . . . . . . . . . . . . . . 82-500-01.028
1a Cover platelet . . . . . . . . . . . . . . . . 82-100-03.290
2 Functional part
Shower systems . . . . . . . . . . . 82-100-20.389
Washing bays . . . . . . . . . . . . . 82-100-20.390
3 Valve seat with O-ring . . . . . . . . . . 82-500-01.017
4 Slide-on rosette . . . . . . . . . . . . . . 82-100-10.397
Spare parts kit consisting of:
Rubber parts
Pressure spring
Circlip . . . . . . . . . . . . . . . . . . . 82-500-01.009
6
Cause
– Stop valve is closed
– Functional part faulty
– Functional part faulty
– Shower head/outlet is clogged with dirt
– Supply pressure too low
– Water volume regulator is not fully opened
– Incorrect setting
– Shower head/outlet is clogged with dirt
– Functional part faulty
Order No.
Chapter
10.).
Remedy
➯ Open it
➯ Replace it
➯ Replace it
➯ Cleaning
➯ Check it
➯ Open it
➯ Adjust it
➯ Cleaning
➯ Replace it

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Aqrm6682195 00 23Aqua206

Table des Matières