Values And Units Used - Ecolab LMIT 08 Notice Technique

Transmetteur pour le mesurage sans électrode de la conductivité et de la température
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Power supply
Supply voltage:
Tolerance:
Power consumption:
Fuse protection:
Electrical connection:
Ambient conditions
Permitted ambient temperature:
Influence of ambient temperature:
Influence of supply voltage:
Permitted vibration:
Accuracy of conductivity measuring (referring to current output)
conductivity measuring ranges:
Linearity:
Reproducability:
Zero point error:
Load dependence:
Stored product data:
HNO
3
H
SO
2
4
NaOH
P3-aquanta BI
P3-aquanta SI
P3-AR extra
P3-cosa CIP 72
P3-cosa CIP 77
P3-cosa CIP 92
P3-cosa CIP 95
P3-cosa PUR 83
P3-cosa PUR 84
CIP version
additional to BASIC version:
- 4 externally selectable CIP configurations and current output assignments
- Selection of CIP configurations is effected by 24 V AC/DC signals
PROFIBUS version
additional to BASIC version:
- 4 externally selectable configurations and current output assignments
- External configuration and parameterization (DPV1) and fault and status signals.
- Interface
- Baud rate
- Connection resistance:
In order to keep our products completely up to date, we reserve the right to make technical
NOTE
modifications.
13.1

Values and units used:

Symbol
Physical values
χ
Electrical conductivity
G
Electric conductance
R
Electrical resistance
I
Electric current
U
Voltage
Temperature coefficient
Tkα
ϑ
Absolute temperature
T
Thermodynamic temperature
Absolute temperatures are quoted in units of °C, but temperature coefficients are usually
NOTE
quoted in K (Kelvin).
417101109_LMIT08.doc
24 V AC oder DC
+/- 15 %
approx. 6 VA
5 x 20 mm miniature fuse 400 mA, slow-acting
plug-in screw terminals
0 ... 50°C
< 0,2 % / 10 K within the permitted range
< 0,5 % within the permitted range
10 ... 150 Hz, 20 m/s
for standard instruments: 0...2/20/200 mS/cm and 0...2 S/cm
for Pharma instruments: 0...200 µS/cm, 0...2/20/200 mS/cm and 0...2 S/cm
< 0,5 % of final value + 1 digit
< 0,5 % of final value + 1 digit
< 0,5 % of final value + 1 digit
< 0,2 %/100 Ω load change
P3-flüssig 141
P3-horolith TR
P3-flüssig 2083
P3-horolith USP
P3-flüssig OS
P3-horolith V
P3-horolith 283
P3-liquid CIP
P3-horolith BSR
P3-liquid OS
P3-horolith CD
P3-mip 100
P3-horolith CIP
P3-mip AH
P3-horolith FL
P3-mip ALU
P3-horolith KEG
P3-mip CIP
P3-horolith MSW
P3-mip EA
P3-horolith PA
P3-mip FL
PA P3-horolith PM
P3-mip flüssig
RS 485
9,6 kBaud up to 12 MBaud automatic Baud rate selection
120 Ω, to be switched in, wire type A
- 83 -
2
P3-mip HP
P3-mip LF/LFT
P3-mip LH
P3-mip RC
P3-mip SP
P3-mip TK
P3-mip VA
P3-mip VL
P3-mip zentra
P3-N421
P3-oxonia active S
P3-polix XT
Unit
S/cm
Siemens/cm
S
Siemens
Ω
Ohm
A
Ampere
V
Volt
%/K
% / Kelvin
°C
Celsius
K
Kelvin
P3-Rinsa black
P3-SR395
P3-tresolin CIP
P3-trimeta CID
P3-trimeta CIDsp
P3-trimeta Duo
P3-trimeta ES
P3-trimeta HC
P3-trimeta MS
P3-trimeta OP
Rev. 3-01.10