6.
Functional Discription
6.1
Equipment versions
6.1.1
BASIC Version
The BASIC version of the
necessary functions for monitoring and making up the concentration of conductive media.
Equipment versions:
I
Compact unit with integrated transducer for pipe installation
II
Wall-mounted version with separate transducer for pipe installation
Transmitter (high-grade steel housing, Protection classification to IP 67) with
inductive, maintenance-free transducer
•
measuring signal output for conductivity or concentration and temperature
0(4)...20 mA (electrically isolated)
•
measuring-ranges: 5 conductivity measuring ranges: 0..200 μs/cm to 0 ...2 S/cm
•
3 concentration measurement ranges:
(0...5 % by weight) for standard cleaning products (NaOH, HN0
•
more than 30 concentration measuring ranges (0..5 % by weight) for
products (eg. horolith)
•
automatic measuring range switch-over between
2 mS/cm, 20 mS/cm, 200 mS/cm, 2 S/cm
•
temperature measurement with PT 100 -50 °C to 140 °C (rapid response time)
•
printer interface RS 232 for documenting the configuration values
•
illuminated display (2-line, 16 characters) with permanent display of conductivity/
concentration and temperature
•
menu-driven operation (multilanguage plain text-dialog-operation:
German, English, French, Spanish)
•
measuring cell made from PEEK, resistant to pressure (16 bar/20 °C), chemicals
and temperature (140 °C)
•
universal - voltage supply: 24V AC/DC
•
Compact version (transmitter with integrated transducer)
-
-
•
Wall-mounted version (transmitter with separate transducer, cable length 5 m)
-
-
417101109_LMIT08.doc
LMIT 08
Order-No. 189101, Clamping ring attachment
Order-No. 189119, Flange connection
Order-No. 189102, Clamping ring attachment
Order-No. 189120, Flange connection
conductivity / temperature transmitter contains all the
- 56 -
, H
S0
)
3
2
4
Ecolab
-Ecolab
Rev. 3-01.10