Cip Version; Profibus Dpv1 Version - Ecolab LMIT 08 Notice Technique

Transmetteur pour le mesurage sans électrode de la conductivité et de la température
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6.1.2

CIP Version

The conductivity / temperature transmitter
separating the phases of conductive media.
Equipment versions:
I
Compact unit with integrated transducer for pipe installation
II
Wall-mounted version with separate transducer for pipe installation
The CIP version contains all the facilities of the BASIC version as well as the following:
4 externally selectable CIP configurations with:
-
conductivity or concentration measuring range
-
TCα value (only for conductivity measurement)
-
Current output assignment
Compact version (transmitter with integrated transducer):
-
Order-No. 189103, Clamping ring attachment
-
Order-No. 189121, Flange connection
Wall-mounted version (transmitter with separate transducer, cable length, 5 m):
-
Order-No. 189104, Clamping ring attachment
-
Order-No. 189122, Flange connection
The CIP or BUS modules are of the plug-in type. These modules can be replaced or
NOTE
retrofitted at any time.
6.1.3

PROFIBUS DPV1 version

The conductivity/temperature transmitter
works with the PROFIBUS DPV1 protocol. For connection to the bus system the
screw terminals.
In its "PROFIBUS DPV1" version the conductivity / temperature transmitter
all the functions necessary for separating the phases, as well as monitoring and making up of
concentration of conductive media.
The PROFIBUS DPV1 version contains all the facilities of the BASIC and CIP version, as
well as the following:
• configuration and parameterization without direct manipulation of the transmitter
• data transfer of conductivity/concentration and temperature
• transfer of status and fault messages
• choice of the CIP configurations
• max. 32 transmitters (with repeater, 127 units) on one bus line
• PROFIBUS connection without additional equipment and installation cost
• Compact version (transmitter with integrated transducer)
-
Order-No. 189142 Clamping ring attachment
-
Order-No. 189150 Flange connection
• Wall-mounted version (transmitter with separate transducer, cable length 5 m)
-
Order-No. 189143 Clamping ring attachment
-
Order-No. 189151 Flange connection
417101109_LMIT08.doc
LMIT 08
embodies all the functions necessary for
LMIT 08
can be integrated in a field bus system, which
- 57 -
LMIT 08
has
LMIT 08
embodies
Rev. 3-01.10