Do not under any circumstances use
grinding discs as the cutting tool.
Before replacing the saw blade, it is strongly
advised to set the mitre angle and bevel angle to
0°. Otherwise, access could be limited.
• Disconnect the machine from the power supply.
• Remove the screw (33) that holds the retraction
arm to the blade cover.
• Remove the screw (40) in order to remove
the bolt-cover by lifting the blade cover (5)
upwards.
• Both saw blade bolt (42) and Flange (41) should
be visible now like shown in fig. E.
• Press the saw blade lock button (43) Rotate
the saw blade carefully by hand until the blade
locks.
• Use hex key to remove the saw blade bolt (42)
by loosening in a clockwise direction.
• Remove the Flange (41) and the saw blade
• Replace the saw blade making sure that the
arrow marked on the saw blade must point in
the same direction as the arrow shown marked
on the machine. The saw blade teeth must
point downwards.
• Fix the saw blade bolt (42) use the saw blade
lock button (43) in order to secure tightly
• Lower the blade cover (5) in order for the bolt
cover to fall back into place and tighten the
screw (40)
• Attach the retraction arm back onto the blade
cover (5) by tightening the screw (33)
• Rotate the saw blade and check if the guard
operates freely
Dust extraction
Fig. A, B, T
Provide good ventilation at the
workplace.
Wear dust protection.
The dust from materials such as lead paint and
some types of wood can be harmful to your
health. Breathing in this dust can cause allergic
reactions and/or cause respiratory illnesses for
the user or people in the near vicinity. Certain
dusts, such as oak or beech dust, are classified
as carcinogenic, especially in conjunction with
wood treatment additives (chromate, wood
preservative). We strongly advise to use a dust
extraction system that is suitable for the material
wherever possible.
Avoid dust accumulation at the
workplace. Dust can easily ignite.
The dust extraction system can be blocked by
dust, chips or fragments of the workpiece. Thus, it
must be cleaned regularly. To do so:
1. Disconnect the mains plug from the power
supply.
2. Wait until the saw blade has come to a
complete stop.
3. Remove any blockage if necessary
Mounting the dust bag
Fig. A, B
Press in the clamp of the dust bag (26) and
slide it onto the dust outlet (28) on the back of
the machine. The dust bag stays in place when
releasing the clamp.
Connecting a vacuum cleaner
Fig. A, B, T
The dust extractor must be suitable for
the material being worked.
When vacuuming dry dust that is
especially detrimental to health or
carcinogenic, use a special dust extractor.
A vacuum cleaner hose can be connected to the
dust outlet (28). To do so, simply connect the
vacuum hose to the dust extraction spout.
4. OPERATION
Before you turn on the machine, always
check that the saw blade is fitted
correctly. The blade must turn smoothly.
Always check the protective guards
before use.