4 Putting into operation
4.3 Mounting the wire guide
NOTICE
• Only use gas-tight, plastic-insulated wire guides to ensure a secure shielding gas cover
and a defined current contact.
• Bare liners give rise to a loss of shielding gas.
4.3.1 Liner
NOTICE
• New and unused liners must be abridged to the actual length of the cable assembly.
• To install the wire guide with a little preload, excess length is required.
 Fig. 3 Liner on page EN-8
To be used for steel wires.
1
1
Torch neck
2
Inlet nipple
3
Wire conduit
Fig. 3
Liner
1 Lay down the cable assembly (9) straight and unscrew nut (6) from central connector (4).
2 Slide the liner (8) through the wire conduit (3) until a noticeable resistance is felt in the inlet
nipple (2).
3 Determine excess length x and pull out the liner (8) again.
4 Shorten the liner (8) by the dimension x.
5 Debur the cutting point and sharpen the spiral beginning to an angle of 40°.
6 Insert the liner cut to length (8) into the wire conduit (3).
EN - 8
2
3
40°
9
8
4
Central connector
5
Multiple wrench
6
Nut
PP Plus 36D/240D/401D
4
4 – 5 mm
x
7
7
Holding nipple
8
Liner
9
Cable assembly
BAL.0140 • 2018-10-15