Saving, Displaying And Deleting Measured Values; Error Messages/Troubleshooting - Beurer BM 27 Mode D'emploi

Masquer les pouces Voir aussi pour BM 27:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 31
Blood pressure
Systole
value category
(in mmHg)
High normal
130 – 139 85 – 89
Normal
120 – 129 80 – 84
Optimal
< 120
Source: WHO, 1999 (World Health Organization)
7. Saving, displaying and deleting measured
values
The results of every successful measurement are stored
together with the date and time. If there are more than 30
measurements, the oldest measurements are lost.
• Press the memory button M. Select the desired user
memory (
...
) by pressing the memory button M again.
• If you press the function button +, the average value of
all the stored measured values in the user memory will be
displayed. If you press the function button + again, the
average value of the morning measurements for the last
7 days will be displayed (morning: 5 a.m. – 9 a.m., display
). If you press the function button + again, the average
value of the evening measurements for the last 7 days will
be displayed (evening: 6 p.m. – 8 p.m., display
continue to press the function button +, the most recent
Diastole
Action
(in mmHg)
regular monito-
ring by doctor
self-monitoring
< 80
self-monitoring
). If you
individual measured values are displayed in turn with the
date and time.
• To switch off, press the START/STOP button
• If you forget to switch off the device, it will switch itself off
automatically after 30 seconds.
• If you want to delete the whole memory for a specific
user, press the memory button M. Press and hold down
the memory button M and the setting button SET simulta-
neously for 5 seconds.

8. Error messages/troubleshooting

In the event of errors, the error message _ appears on the
screen. Error messages may appear if:
• It was not possible to correctly record the pulse:
• No measurement could be taken:
• The cuff is fastened too tightly or loosely:
• Errors occur during the measurement:
• The pump pressure is higher than 300 mmHg:
• There is a system error. If this error message appears,
please contact Customer Services:
• The batteries are almost empty:
In such cases, repeat the measurement. Ensure that the cuff
line is correctly attached and that you do not move or speak
during the measurement.
If necessary, reinsert or replace the batteries.
27
.
1
;
2
;
3
;
4
;
5
;
6
.
.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

65818

Table des Matières