Abicor Binzel iSTM Mode D'emploi page 41

Masquer les pouces Voir aussi pour iSTM:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

iSTM
9.2 iSTM Cleaning the ABIROB
1
Set screw M3x3
2
2 pressure springs
3
2 O-rings 7x1.5
Abb. 11
iSTM Cleaning the ABIROB
®
W
1
8
7
4
4 O-rings 3.5 x 1.5
5
2 size cylinders
6
2 balls
®
W
1 Remove balls (6), pressure springs (2) and size cylinders (5), check them
for damage and replace them if necessary.
2 Check the O-rings (3), (4), and replace them if necessary.
WARNING
Risk of injury
Serious injuries caused by parts swirling around.
• When cleaning with compressed air, wear suitable protective clothing, in
particular safety goggles.
3 Clean the ABIROB
4 Grease the O-rings (3), (4) with sealing grease (included in the scope of
delivery).
5 Mount the O-rings (3), (4) onto the size cylinders (5).
6 Mount the balls (6), pressure springs (2) and size cylinders (5).
7 Dismount the set screw (1) and gas guide (8) and check them; if necessary
replace and remount them.
After the
NOTE
Carry out a functional check after mounting the iSTM mount.
• Mounting the cable assembly
• Switching on the recirculation cooler
• Carrying out a tightness check (visual check for coolant loss)
9 Maintenance and cleaning
2
3
6
7
8
®
W (7)iSTM mount with compressed air.
4
5
®
ABIROB
W iSTM mount
Gas guide
EN - 19