 Remove the condensed water. Run the unit for a few hours on fan function so
that the unit is completely dry inside.
 Then switch the air conditioning unit off and remove the plug from the socket.
 Clean the filters and reposition them or replace with a new ones.
 Unscrew the waste pipe from the device in order to prevent damage.
 Pack the air conditioning unit in its original packaging or in a plastic bag and
place in a dry place for storage. Place a heavy object on the unit.
 Remove the batteries from the remote control.
 Store the device in a room smaller than 15m².

Troubleshooting and error codes

Troubleshooting
The unit does not start if I press the ON/OFF button
 Is the plug in the socket?
 Is the earth leakage circuit breaker engaged? No power?
 Is the water tank full? Empty it.
 The room temperature is lower than the set temperature; amend the set
temperature.
The unit doesn't seem to be very effective
 Measure the outlet temperature; this must be approx. 10° cooler than room
temperature.
 Is there direct sunlight? Shut the curtains.
 Are windows or doors open? Shut them.
 Are there too many people in the room? They produce heat!
 Is the space too big?
 Is there an object in the room that is generating (a great deal of) heat? Switch it
off or remove it.
 Are the filters dusty or covered in dirt? Clean them.
 Is the air inlet or outlet (hose) blocked? Make sure there is free air flow.
The unit is making a noise
 Is the surface underneath the machine sturdy and even?
 The flow of coolant in the unit also produces a little noise. This is perfectly
normal.
The unit switches itself off
 The overheating safeguard may have switched the unit off. See 'Safety'.
Error codes
Error code
Cause
E0
Error temperature sensor
E1
Condenser temperature
sensor defective
E2
Water tank is full during
cooling
What to do
Have it replaced. The unit works
without temperature setting.
Have the sensor replaced by an
authorized and qualified person.
Switch off the appliance and empty the
water tank manually via the lower
51