Troubleshooting - Emerson GEODE CF370BS00 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE
TROUBLESHOOTING YOUR FAN.
TROUBLE
1. Fan will not start. 1. Fuse or Circuit Breaker blown.
2. Loose Power Line Connections to the Fan.
3. Reverse Switch in Neutral position.
2. Fan sounds
1. Blades not attached to Fan.
noisy.
2. Screws securing Fan Blades to Motor are
loose.
3. Loose Screws in Motor Housing.
4. Wire connectors inside switch housing
rattling.
5. Motor noise caused by solid-state variable
speed controls.
6. Screws holding blades to flanges are loose.
3. Fan wobbles
1. Set Screws in Motor Coupler are not
excessively.
tightened securely.
2. Set Screw in the Hanger Ball/Downrod
Assembly is loose.
3. Screws securing Fan Blades to Motor
are loose.
4. Fan Blades are not seated properly.
5. Hanger Bracket and/or Ceiling Outlet Box
is not securely fastened.
6. Fan Blades out of balance.
4. LED Light fixture 1. Loose Electrical Connectors.
will not
illuminate.

13. Troubleshooting

!
PROBABLE CAUSE
WARNING
SUGGESTED REMEDY
1. Check Main and Branch Circuit Fuses or Circuit Breakers.
Make sure main power is turned OFF.
2. Check Line power connections to Fan.
3. Make sure Reverse Switch position is all the way to one
side.
1. Attach Blades to Fan before operating.
2. Check to make sure the Screws which attach the Blades
to the Motor are tight.
Make sure main power is turned OFF.
3. Check to make sure all Screws in Motor Housing are.
snug (Not Over-Tight).
4. Check to make sure wire connectors in switch housing are
not rattling against each other or against the interior wall
of the switch housing.
5. Some fan motors are sensitive to signals from solid-state
variable speed control. If solid-state control is used and
motor noise results, choose an alternative control method.
6. Tighten screws securely.
1. Raise Coupler Cover and tighten Set Screws securely.
2. Tighten the Set Screw in the Hanger Ball/Downrod
Assembly.
3. Check to be sure Screws which attach the Fan Blades
to the Motor are tight.
4. Check to be sure that the Screws securing the Fan
Blades seat firmly.
5. Tighten the Hanger Bracket Screws to the Outlet Box,
and/or secure Outlet Box.
6. Interchanging an adjacent (side by-side) Blade pair can
redistribute the weight and result in smoother operation.
Or use supplied Balancing Kit to balance Blades.
1. Shut off the Branch Circuit Electricity at the Fuse Box or
Breaker Panel and check the LED Light Fixture
Assembly Electrical Connector for proper installation.
Please contact 1-800-654-3545 for further assistance
27
WARNING
!
WARNING
!
emersonfans.com
ETL Model No.: CF370

Publicité

Table des Matières
loading

Table des Matières