Fault
play
32
Excess current outlets CAN Bus module A10
(main plate)
33
CAN bus fault in module 17 – no connection
34
Overcurrent outlets CAN Bus module 17
35
Excess current outlets CAN Bus module A14
(water distributor)
36
Excess current outlets CAN Bus module A13
(feed distributor)
40
Excess current outlets CAN Bus module A21
(anti-frost)
45
Excess current outlets CAN Bus module A26
(Interface wash card reader in feed distributor)
46
Excess current outlets CAN Bus module A27
(high pressure pumps)
49
E_prom checksum error
50
Limit switch FA (drive start) has not been exit-
ed despite driving command
51
Limit switch FA (Drive start) has not reached
expected position
52
Limit switch FE (drive end) has not been exit-
ed despite driving command
53
Limit switch FE (Drive end) has not reached
expected position
54
Travel command has been given but SB1A
(side brush 1, outward) limit switch has not
been exited
55
Limit switch SB1A (side brush 1, outward) has
not reached expected position
56
Travel command has been given but SB1E
(side brush 1, driven-in) limit switch has not
been exited
57
Limit switch SB1E (side brush 1, driven-in) has
not reached expected position
58
Travel command has been given but SB2A
(side brush 2, outward) limit switch has not
been exited
59
Limit switch SB2A (side brush 2, outward) has
not reached expected position
60
Travel command has been given but SB2E
(side brush 2, driven-in) limit switch has not
been exited
61
Limit switch SB2E (side brush 2, driven-in) has
not reached expected position
62
Travel command has been given but DBO (top roof
brush) limit switch has not been exited
63
Limit switch DBO (top roof brush) has not
reached expected position
66
Travel command has been given but DBU limit
switch (lower roof brush) has not been exited
67
Limit switch DBU (lower roof brush) has not
reached expected position
68
Limit switch TrO / HdO not vacated despite
travel command (8 seconds after activation of
drive).
69
Limit switch TrO / HdO not reached (counter
status exceeds limit by 50 cm)
70
Limit switch TrU / HdU not vacated despite
travel command (8 seconds after activation of
drive).
71
Limit switch TrU / HdU not reached (counter
status exceeds limit by -50 cm)
Possible cause
Short circuit, water leakage
Connection cable of the PCB loose, PCB
defective
Short circuit, water leakage
Error in main plate
Limit switch activated through foreign
metal or is defective
Limit switch defective or lifting system de-
fective
17
-
EN
Remedy
Switch off and switch on the unit, re-
peat washing process, call Customer
Service
Check limit switch portal driving for
defects; remove metal parts from the
hall floor; switch off/on the unit, re-
peat washing process, call Customer
Service
Check limit switch of the side brushes
for damages, switch on/ off the unit,
repeat washing process
Check the limit switch for damage,
check the lifting system, switch the
plant off and back on, repeat the
washing process.