9.9. Light barrier

This menu item allows you to program the effect of the light barrier after
it has been activated:

9.10. SE1 (closing)

In this menu item you can set whether the controller is to monitor the
safety input SE1 (terminal 32) for an 8.2kΩ resistor (safety contact strip)
or for an OES strip (optoelectronic safety contact strip).
x 8k2
x OES
Furthermore, the effect of actuating the safety input must be selected
(only effective when closing!):
x NO Effect
x Stop
x Disengage (ca. 1 sec)
x Reverse
NO
Effect
OPEN
Stop
OPEN
Disengage (ca. 1 sec)
OPEN
Reverse
CLOSE Stop
CLOSE Disengage (ca. 1 sec)
CLOSE Reverse
26