Delete Data; Cycle Counter; Version; Motor Parameter - BelFox 47-21-i Mode D'emploi

Masquer les pouces Voir aussi pour 47-21-i:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 98

9.23. Delete data

This menu item allows you to delete the following data:
1: -----
No deletion
2: Forces
Deletion of memorized forces
3: Distances +
Deletion of memorized end of travel positions and
Forces
forces
4: Configurations Deletion of all memorized configurations

9.24. Cycle counter

This menu item is a pure display menu, here you can read the number of
runs made so far. This value cannot be deleted or reset.

9.25. Version

This menu item is a pure display menu, here you can see which software
version is programmed in the control unit.

9.26. Motor parameter

This menu item is a display menu for the motor parameter.

9.27. Emergency function

In this menu item you can activate or deactivate the emergency function
(see section 7.5.: Button inputs A-D). After a RESET of the control, the
emergency function is inactive.

9.28. Restart

In this menu item you can activate or deactivate the restart.
If an active command is detected at inputs A-D after the voltage has been
switched on, the controls start the motor to assume the desired status /
end position. If an additional safety input is detected as active, the start to
the end position is not carried out.
Input A
Input B
Input C
After a RESET of the control, the restart is inactive.
With automatic closing – Starts opening the
gate and keeps the gate open
Starts opening in the mode "Open without
stop".
Starts closing in the mode "Close without
stop".
31

Publicité

Table des Matières
loading

Produits Connexes pour BelFox 47-21-i

Table des Matières