BelFox 47-21-i Mode D'emploi page 59

Masquer les pouces Voir aussi pour 47-21-i:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 98
5 5 . . I I n n s s t t a a l l l l a a t t i i o o n n o o f f t t h h e e m m o o t t o o r r c c o o n n t t r r o o l l
Deadly electric shock from mains voltage possible!
There is a danger of life-threatening / fatal electric shock when in contact with
the mains voltage.
SAFETY INSTRUCTION FOR HAZARD AVOIDANCE
x Electrical connections must only be carried out by a qualified
electrician.
x When laying the power line, the applicable regulations must be observed
and complied with (IEC 364-4-41).
x Disconnect the system from the power supply before carrying out any
work. Secure the system against unauthorized restarting.
x Ensure that the on-site electrical installation complies with the relevant
safety regulations.
x To avoid hazards, a damaged power cord must be replaced by an electri-
cian with an intact power cord.
x Use protective equipment during assembly.
x
Reliable operation is only possible if the unit is carefully installed in ac-
cordance with these instructions. Switch on the mains voltage only after
a second inspection.
If the instructions are not followed, the controls may be
destroyed!
Penetrating moisture or dirt can permanently damage or destroy the controller.
Incorrectly connected cables can lead to malfunctions or destruction of the
controller.
SAFETY INSTRUCTION FOR HAZARD AVOIDANCE
x 230 V lines (terminals 1 to 8 of the terminal strip) and control lines (ter-
minals 9 to 36) must be laid in separate cable ducts to avoid interference.
x NEVER switch 230 V mains voltage to the control inputs (terminals 9 to
36). In case of non-observance, immediate destruction,
no warranty!
DANGER
ATTENTION
11

Publicité

Table des Matières
loading

Produits Connexes pour BelFox 47-21-i

Table des Matières