9.6. B Opening

In this menu item you can determine the mode of action of input B:
x Stop panic (Open-Stop-...)
x Stop no panic (Open-Open-...)
x Deadman (Press-and-hold travel: the gate opens only as long as the
respective button is pressed)
x Limit switch ((limit switch closed with DIN left or limit switch open
with DIN right)

9.7. C Closing

In this menu item you can determine the mode of action of input C:
x Stop panic (Close-Stop-...)
x Stop no panic (Close-Close-...)
x Deadman (Press-and-hold travel: the gate closes only as the corre-
sponding button is pushed)
x Limit switch (limit switch closed with DIN left or limit switch open
with DIN right)

9.8. D Partial-opening (PO)

In this menu item you can determine the mode of action of input D:
x Stop panic (PO-Stop-Close-Stop...)
x Stop no panic (PO-PO-...)
x Auto closing OFF (Automatic closing turned off.)
x Limit switch (Limit switch OPEN with DIN-left or limit switch CLOSED
with DIN-Right.)
Furthermore, the percentage of the partial opening' travel distance (as
compared to the total travel distance) must be set here. It must be less
than 100%.
If input D is permanently activated and the gate is closed from end posi-
tion OPEN with automatic closing and no limit switch is set, the system
only closes up to the partial opening position (personnel entrance).