SE 1
The safety inputs flash
SE 2
if the safety input 1
(SE1) or the safety in-
put 2 (SE2) has been
activated
F1
Radio commands which
to
are given by the radio
F9
transmitter
E-A
Limit switch OPEN /
E-Z
CLOSED
Flashes when the limit
switch OPEN / CLOSED
is activated
?
End positions not syn-
chronized after power
failure
####
Learning runs not yet
carried out.
SE 1 flashes
SE 2 flashes
Flashes though neither of
the remote control has
been activated
Lights up although the gate
is not in an end position
44
tact of the safety contact edge have been
interchanged
Use a rest contact
Ö
► The safety contact edge is active
Inactivate it
Ö
►The safety contact edge is defective
Replace it
Ö
► False configuration (Menu item 10)
8K2 by default
Ö
► The wire of the safety contact edge is de-
fective or pulled
Repair the wire / replace it
Ö
► The safety contact edge is active
Inactivate it
Ö
►The safety contact edge is defective
Replace it
Ö
► False configuration (Menu item 11)
8K2 by default
Ö
► The wire of the safety contact edge is de-
fective or pulled
Repair the wire / replace it
Ö
► Another hand transmitter in the immedi-
ate vicinity has the same coding (12-bit en-
coding)
Use an 18-bit encoding or a different
Ö
one.
► An neighbouring hand transmitter has
wrongly been taught in
Delete individual hand transmitters
Ö
(18-bit encoding)
- Check limit switch.
- Menu Input A-D incorrectly set.
Move the actuator with the magnet over the
reference switch or to the end positions.
Carry out learning trips