Last Commands; Status Display (Motor) - BelFox 47-21-i Mode D'emploi

Masquer les pouces Voir aussi pour 47-21-i:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 98
SE2-HW
Safety input 2- Self test t (Hardware)
CEL-HW
Light barrier- Self test (Hardware)
Monoimp
No motor impulse or no motor current
runtime
Safety input 2: active during engine opera-
tion
HiVfaul
Overvoltage
LoVfaul
Low voltage
DirMfaul
The motor turns in the wrong direction

13.2. Last commands

To be able to read out the last commands for troubleshooting, press the
"Escape/Menu" key until the display shows "Last commands". Confirm
this with the "
/ Return" key.
Now you can read out the last 50 commands which have affected the
control with the keys "↑ +" and "↓ -", furthermore you are shown the
time before which the command was given.

13.3. Status display (motor)

To operate the gate using the control keys, press the "Escape/Menu" key
until the display shows "Last commands". Now press the "Escape/Menu"
key again.
Now the current status of the motor is shown in the first line of the dis-
play. The second line of the display shows you the currently activated/
operated inputs.
Z1
Hall sensor 1 actuated in motor (lights up several
times during motor run)
Z2
Hall sensor 2 actuated in motor (lights up several
times during motor run)
REF
Reference switch actuated
A
Input A impulse closed (actuated)
B
Input B-Opening closed (actuated)
C
Input C-Closing closed (actuated)
D
Input D partial opening closed (actuated)
the board
Check the connection / Replace
the board
Check the connection / Replace
the board
Check the connection / Replace
the board
Check the limit switch / check
the mechanism
Check mains supply or replace
the board
Check mains supply / check the
mechanism / replace the board
Check mains supply or Replace
the board
41
SL6 Ts 21 & 22
SL6 Ts 22 & 23
SL6 Ts 24 & 25
SL6 Ts 25 & 26

Publicité

Table des Matières
loading

Table des Matières