OPERATING YOUR DEHUMIDIFIER

Set unit upright
Always operate the dehumidifier in an upright position. If
the unit has been stored or transported in a horizontal
position, set it upright (in a vertical position) for at least
30 minutes before operating it. This will allow for any
compressor oil that has flowed into the refrigerant coils
to return to the compressor and allow the dehumidifier to
function properly.
Set up drain hose
The Evolution LGR pump connects to a plastic drainage
hose. The hose can be stored on the hose wrap, located
on the back of the unit (see Fig. A). You can release the
hose by rotating the top reel of the hose wrap to either
side; pull the tab outward until you're able to rotate it
(see Fig. C). Rotate the tab to the right or left until it is
pointing straight down. This feature makes it easy to
take off the entire hose quickly. Place the unattached
hose end in a sink, drain, bucket – even outside;
anywhere that water can drain out safely.
NOTE: Uncoil and straighten the entire drain hose.
Do not leave any of part of the hose coiled on the
unit and do not place the end of the hose higher
than 20 ft. (6 m) above the top of the unit. Also
check for kinks, or obstructions that would restrict
the flow of water. Failure to do so may cause a water
backup in the pump resulting in leakage.
Plug in electrical cord
The electrical cord is wrapped around the top of the unit.
The Evolution will operate on any standard 115-volt (15
amp) grounded outlet.
If the unit experiences a loss of power, either from a
power interruption or from thermal overload protection,
FIG. D: FRONT
07-01480C 2010-01
Control panel
Molded cord storage.
Process (dehumidified)
air outlet. May be used
with standard 12 in.
rigid or layflat ducting.
Air filter access
door. Lift handle
to release.
Humid air inlet (both
sides of door).
let the unit rest for five minutes before restarting.
Otherwise it might shut off again.
Turn the unit on
Press the "on" button on the touchpad.
How to use the control panel
The Touchpad on DrizAir dehumidifiers has one display
and four keys. The normal display messages are
DEHUMIDIFIER OFF
DEHUMIDIFIER ON
TOTAL HRS
JOB HRS
When the unit is first connected to AC power, the
touchpad display will cycle continuously through three
messages: DEHUMIDIFER OFF, TOTAL HOURS, and
JOB HOURS.
ON-OFF. Press the ON-OFF key to turn the unit on
or off. When turning the machine on, usually the display
reads CMPRSR DELAY and performs a numeral count
down from a maximum of 60 seconds to 0. The
compressor delay gives the machine time to warm up
(when needed). If you don't see a compressor delay
countdown, the machine is ready to go. Once the unit
completes the CMPRSR DELAY, the display reads
DEHUMIDIFIER ON, and continues to cycle between
TOTAL HOURS, JOB HOURS and DEHUMIDIFIER ON.
Press the ON-OFF key again to turn the unit off. The
display will read DEHUMIDIFIER OFF.
DISPLAY. Press the DISPLAY key to stop the
display at DEHUMIDIFER ON or OFF, TOTAL HOURS,
or JOB HOURS as it cycles. Press DISPLAY again to re-
start the display cycle.
3
CMPRSR DELAY
PUMP PURGING
DEFROST ON
GET SERVICE ERXX