How the Revolution works
The Revolution refrigerant dehumidifier uses a fan to
draw moist air in and condenses it into water that col-
lects in a tray and is automatically pumped out through a
drain hose. The unit can be set to operate continuously
or the user may select Humidistat Mode. In Humidistat
Mode, the Revolution will turn on and off automatically to
maintain the inlet humidity level the user has selected.
CONTROLS AND OPERATING INSTRUC-
TIONS
Set unit upright
NOTICE: Always store, transport, and use the unit in
a horizontal position. If the unit is ever placed in a
vertical position, return it to the horizontal position
and let it stand for at least 30 minutes before turning
it on.

Positioning a Dehumidifier

For best results, operate your dehumidifiers in an en-
closed area. Close all doors and windows that open to
the outside to maximize water removal efficiency. Place
your dehumidifier away from obstructions, and keep it
away from anything that could block airflow into and out
of the unit.
Set up drain hose
This unit automatically pumps out water on a regular ba-
sis. This dehumidifier is equipped with a quick-connect
fitting for attachment to the provided 40 ft. (12 m) drain
hose located in the tray on top of the unit. Unwrap the
entire hose and place the open end in a sink, drain,
bucket or outdoors – anywhere that water can drain out
safely. If you use a bucket or other container for water
collection, check it regularly to prevent overflows.
NOTICE: Uncoil and straighten the entire drain hose. Do
not leave any part of the hose coiled and do not place
the end of the hose higher than 20 ft. (6 m) above the
bottom of the unit. Also check for kinks or other obstruc-
tions that might restrict the flow of water. Obstructions
may cause a water backup and result in overflows.
110485K (07-01839) F413
Fig. A: Parts Identification
Air inlet
Cord and
hose storage
wraps.
Condensate
drain quick-
connect
Plug in electrical cord
The Revolution should be plugged into a GFCI-pro-
tected 115 volt outlet rated for at least 15 amps. Always
plug the cord firmly into the unit first, and then plug the
other end into a suitable outlet.
2
Carry handles
Control
panel
Air outlet
Power
socket
Temp/RH
sensor
Remove/Insert
air filter here.