The Revolution refrigerant dehumidifier uses a fan to
draw moist air in and condenses it into water that col-
lects in a tray and is automatically pumped out through a
drain hose. The unit can be set to operate continuously
or the user may select Humidistat Mode. In Humidistat
Mode, the Revolution will turn on and off automatically to
maintain the inlet humidity level the user has selected.
CONTROLS AND OPERATING INSTRUC-
TIONS
Set unit upright
NOTICE: Always store, transport, and use the unit in
a horizontal position. If the unit is ever placed in a
vertical position, return it to the horizontal position
and let it stand for at least 30 minutes before turning
it on.

Positioning a Dehumidifier

For best results, operate your dehumidifiers in an en-
closed area. Close all doors and windows that open to
the outside to maximize water removal efficiency. Place
your dehumidifier away from obstructions, and keep it
away from anything that could block airflow into and out
of the unit. For more information about creating an opti-
mum drying environment, contact Dri-Eaz at
800-932-3030.
Set up drain hose
This unit automatically pumps out water on a regular ba-
sis. This dehumidifier is equipped with a quick-connect
fitting for attachment to the provided 40 ft. (12 m) drain
hose located in the tray on top of the unit. Unwrap the
entire hose and place the open end in a sink, drain,
bucket or outdoors – anywhere that water can drain out
safely. If you use a bucket or other container for water
collection, check it regularly to prevent overflows.
NOTICE: Uncoil and straighten the entire drain hose. Do
not leave any part of the hose coiled and do not place
the end of the hose higher than 20 ft. (6 m) above the
bottom of the unit. Also check for kinks or other obstruc-
tions that might restrict the flow of water. Obstructions
may cause a water backup and result in overflows.
Plug in electrical cord
The Revolution should be plugged into a GFCI-pro-
tected 115 volt outlet rated for at least 15 amps. Always
plug the cord firmly into the unit first, and then plug the
other end into a suitable outlet.
Startup display and normal display modes
When unit is first plugged in to AC power, the control
panel display will briefly cycle through a series of
readouts. This is part of the unit's self-diagnosis proce-
dure and no user intervention is required.
07-01839F F413-115V
Fig. A: Parts Identification
Air inlet
Cord and
hose storage
wraps.
Condensate
drain quick-
connect
Turn the unit on
The control panel on the Revolution dehumidifier has a
display and a touchpad with four keys. Press the
ON/OFF to turn the unit on. The unit will now go
through a compressor delay countdown (up to sixty sec-
onds in duration) and a self diagnostics process.
Once the compressor delay countdown and self-diag-
nostics are complete, the display will switch to normal
display mode.
UNIT ON 00 HRS
INLET 00°C / INLET 00%
The first line of the display shows the total number of
hours the unit has been in operation. This value may be
reset to zero to track job hours (see "Job Hours Reset"
below). The second line of the display alternates be-
tween inlet temperature and inlet humidity.
User Settings Menu
A number of display settings may be changed by the
user. System information can also be displayed. These
items are accessed by pressing
Each press of the key will display the next parameter.
When you reach the parameter you wish to adjust, press
MENU SELECTION to increase the value. Press
DISPLAY MENU again to accept the setting and re-start
the display cycle.
2
Carry handles
Control
panel
Air outlet
Power
socket
Temp/RH
sensor
Remove/Insert
air filter here.
DISPLAY MENU.