TROUBLESHOOTING
F A U L T
Water drips out
when moving unit
Unit does not op-
erate
Unit operating,
but room not dry
Unit collects too
little water
If the problem you are experiencing is not listed here, call your local distributor or contact
our Service Department toll-free at 800-932-3030 for further assistance.
SPECIFICATIONS
Name
Dimensions (W × H × D)
Weight (w/ cord & hose)
Amps
Power
Air movement
Water removal
Operating temperature range
Safety
Specifications are subject to change without notice. Some values
may be approximate.
WARNING: This product may expose you to
chemicals, including lead and phthalates, known
to the State of California to cause cancer, birth defects,
or other reproductive harm. For more information, go to
P65Warnings.ca.gov
07-01839F F413-115V
C A U S E
Unit was unplugged before
purging was complete.
Unit not switched on.
No power to machine.
Not enough time to dry.
Poor air movement in room.
Excessive moist air infiltration.
Room air is dry.
Room temperature is too low.
Filter is clogged.
Coils are clogged.
Revolution LGR Dehumidifier
Model F413-115V
12.5 × 17.6 × 21.5 in.
31.8 × 44.7 × 54.6 cm
65 lbs. | 29.5 kg
6.2 amps at 80°F/60% RH
115V / 60Hz
121–180 CFM | 3.43–5.1 CMM
80 pts/day | 38 L/day
at 80°F/60% RH (AHAM)
134 pts/day | 63 L/day
at 90°F/90% RH
33–100°F |1–38°C
ETL listed to CSA standards
S O L U T I O N
Purge unit before moving. See "At the End of the Job," p. 5.
Switch unit on.
Plug in unit; check power cord connection at wall outlet and at
base of unit.
Make sure "Humidistat" is OFF.
Allow more time for drying.
Increase air movement with air movers.
Seal off area to reduce infiltration.
Make sure "Humidistat" is OFF.
Confirm humidity level with hygrometer.
Increase room temperature.
Check filter. Clean as necessary.
Check coils. Clean as necessary.
PARTS INCLUDED
40 ft. (12 m) of drain hose with quick-connect fitting.
25 ft. (7.6 m) detachable power cord.
Air filter reorder no. F583 (24 pk)
OPTIONAL
Duct Attachment Kit (F530)
ADDITIONAL PRODUCT INFORMATION and current
documentation is available at http://Revo.Legend-
BrandsRestoration.com.
FOR PARTS AND SERVICE CALL YOUR LOCAL DIS-
TRIBUTOR or Dri-Eaz at 800-932-3030. Legend-
BrandsRestoration.com
Visit warranty.LegendBrandsRestoration.com and regis-
ter your purchase to ensure you receive any important
product releases.